Laserfiche WebLink
°�'�f�•`� <br />L_ U <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California ROo' 2008 <br />Authority Cited.- Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, Calif ,t (( ode o Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitorii � %1� p A$ � ailed <br />at the facility, a separate certification or report must be prepared for each monitoring system control panel by t tdttti rms the <br />work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this'form`to the local <br />agency regulating UST systems within 30 days of test date. Instructions are printed on the back of this page. <br />A. General Information <br />Facility Name: Econo Gas <br />Bldg. No.: <br />Site Address: 880 E. Victor Road <br />City: Lodi <br />Zip: 95240 <br />Facility Contact Person: Singh <br />Contact Phone No.: <br />(20 9) 369-0958 <br />Make/Model of Monitoring System: Veeder Root TLS 350 <br />_ Date of Testing/Servicing: 12/11/07 <br />B. Inventory of Equipment Tested/Certified <br />Check t e apEopriate boxes to indicatespecific equipment inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 91 <br />X In -Tank Gauging Probe. Model: Mag -1 <br />X In -Tank Gauging Probe. <br />Model: Mag -1 <br />X Annular Space or Vault Sensor. Model: 0794380-301 <br />X Annular Space or Vault Sensor. <br />Model: 0794380301 <br />X Piping Sump / Trench Sensor(s). Model: 0794380-208 <br />X Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. Model: STP MLD <br />X Mechanical Line Leak Detector. <br />Model: LD 2000 <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />X In -Tank Gauging Probe. Model: Mag -1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. Model: 0794380-301 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump / Trench Sensor(s). Model: 0794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. Model: 616-056 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1 & 2 <br />Dispenser ID: 3 & 4 <br />X Dispenser Containment Sensor(s). Model: 208 <br />X Dispenser Containment Sensor(s), <br />Model: 208 <br />X Shear Valve(s). <br />X Shear Valve(s). <br />❑ Dispenser Containment Ficat(s) and Chain(s). <br />❑ Dispenser Containment F'ioat(s) and Chnin(s). <br />Dispenser ID: 5 & 6 <br />Dispenser ID: 7 & 8 <br />X Dispenser Containment Sensor(s). Model: 208 <br />X Dispenser Containment Sensor(s). <br />Model: 208 <br />X Shear Valve(s). <br />X Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9 & 10 <br />Dispenser ID: <br />X Dispenser Containment Sensor(s). Model: 208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />X Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (check all that apply): X System set- X larm history report <br />Technician Name: Ed Stearns Signature: ---- <br />Certification No. A31048 License No. 433159 <br />Testing Company Name: BZ Service Station Maintenance Phone No.: ( 16) 371-2380 <br />Site Address: 630 Houston Street West Sacramento, CA 95691 Date of Testing/Servicing: 12/11/07 <br />Page 1 of 3 <br />