My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br />Page 1 of 8 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />e -h- erground Storage Tank Progra x Pec ion Report <br />. , <br />Facility Name: <br />MARKS FUEL & FOOD INC <br />Facility Phone: <br />209 369-0958 <br />Date: <br />September 14, 2017 <br />Facility Address: <br />880 E VICTOR RD, LODI, CA 95240 <br />CERS ID: <br />10181491 <br />Inspection Contact: <br />Janet Gonzalez <br />Title: <br />Manager <br />Phone: <br />209 <br />369-0958 <br />Inspection Type: <br />ROUTINE INSPECTION - O eratin Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />9 Inspection 0 Photos 0 Samples <br />Consent Given By: <br />Janet Gonzalez, Manager <br />Service Technician Onsite <br />Rhome Desbiens <br />Exp. Date: <br />01/05/2019 <br />Designated Operator: <br />Shawn Rodriguez <br />Exp. Date: <br />05/04/2018 <br />Service Technician Manufacturer's Training <br />Veeder-Root, 03/01/19; VMI Tester,01/09/19 <br />CCR = California Code of Regulations HSC=Health and Safety Code CFR = o e o Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during <br />File Review, <br />101 <br />HSC 25284 <br />No permit to operate <br />V <br />❑ R ❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />V <br />❑ R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />V <br />■ R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />V <br />■ R ❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />V <br />■ R ❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />V <br />❑ R ❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />x V <br />■ R ❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />V <br />❑ R ❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />V <br />❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />V <br />❑ R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />V <br />❑ R ❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />V <br />❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />V <br />❑ R ❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />V <br />❑ R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />V <br />■ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />V <br />❑ R ❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />V <br />❑ R ❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />V <br />❑ R ❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />V <br />❑ R ❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />V <br />❑ R ❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />V <br />■ R ❑ COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />V <br />❑ R ❑ COS <br />Qn Sits Recor'dsT <br />201 CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />V <br />■ R ❑ COS <br />202 CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />V <br />❑ R ❑ COS <br />Page 1 of 8 <br />
The URL can be used to link to this page