My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />'Underground Storage- Tank Progra ' spection Report <br />Facility Name: <br />Facility Address: <br />Date. <br />MARKS FUEL & FOOD INC <br />880 E VICTOR RD, LODI <br />September 14, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or WNOR.- Notice to Comply)` <br />Item # <br />Remarks <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on 9/22/16 and an inspection report was issued identifying information to be submitted <br />to bring this site into compliance. This information was required to be submitted by 10/22/16. This information has <br />not been received resulting in a non-compliant status for this facility. The outstanding violations include: <br />-Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />-Failed to inform the EHD of designated operator identification or change within 30 days. <br />-Failed to submit a written response within 30 days of receiving an inspection report. <br />-Designated operator employee training not performed or log not kept. <br />An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a <br />written response documenting corrective actions taken or proposed is submitted within 30 days of receiving an <br />inspection report. <br />This is a repeat violation, Class II. <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. <br />-The 2016 monitoring system certification test results were not found on site. <br />-Records of alarm responses were not found on site. The missing alarms include: L5 (91 annular) low liquid alarms <br />on 1/25/17, 1/24/17, 1/21/17, 12/27/17, 12/25/17. No alarm logs were observed noting these alarms. No work <br />orders were found on site addressing these alarms. <br />These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br />observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all missing maintenance and monitoring records for the last three <br />years on site and submit copies to the EHD. <br />This is a repeat violation, Class II. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class II. <br />Page 5 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.