My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:40:14 PM
Creation date
6/23/2020 6:51:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
441
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />E <br />Spill Bucket Testing Report Form <br />Thisform is intended for use by contractors performing annual testing (?/' UST spill containment structures. The completed form and <br />, <br />printouts front tests (if applicable), should be provided to theJacilit), owulerloperator.16r submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: Arco AmPrn- Victor Rd Date of Testing: 9/14/2017 <br />0 0' <br />Cit- - Lodi <br />------------------ 0 9 <br />City: Lodi <br />Facility Address: 880 Victor Rd <br />Phone: 209-369 <br />ontact: Karan <br />Facility C <br />- <br />Date Local Agency Was Notified of Testing: Wednesday, August 30, 2017 <br />Name of Local Agency inspector (if present during testing): <br />R <br />2. TESTING CONTRAC4 UK ENVUMVIA I I'k111 <br />Company Name: BZ Service Station Maintenance <br />Technician Conducting Test: Rhorne Desbiens <br />Credentials': CSLB Contractor ICC Service Tech. WRCB Tank Tester ❑Other <br />License Number(s): 433159 <br />3. SPIIA, BUCKET TESTING INFORMATION <br />Test Method Used: <br />Hydrostatic <br />1 87 <br />Direct Bury <br />Fj Contained in Sum <br />lit, <br />13 1/2" <br />L -J Vacuum <br />2 DSL <br />Direct Bury <br />E] Contained in Sum <br />1101 <br />L -J <br />FEquipment Resolution: <br />�7-: <br />771 <br />3 91 <br />Direct Bury <br />E] Contained in Sum <br />III, <br />1/16" <br />4 <br />Direct Bury, <br />Contained in Sum <br />Test Equipment Used: Ruler <br />Identify Spill Bucket (Ay Tank <br />Number, Stored Product, etc) <br />Bucket Installation Type: <br />Bucket Diameter,* <br />13" <br />— <br />13 1/2" <br />Bucket Depth: <br />5min <br />5min <br />5min <br />Wait time between applying <br />vacuum/water and start of test: <br />10:20 <br />10:20 <br />11:57 <br />Test Start Time (Ti): <br />12" <br />11:20 <br />12" <br />lhr <br />12" <br />12" <br />Initial Reading (Rj): <br />11:20 <br />12:57 <br />Test End Time (TO: <br />12" <br />12" <br />Final Reading (RF): <br />— <br />1 h <br />1 h <br />Test Duration (TF - Ti): <br />0 <br />0 <br />Z Pass El Fail <br />0 <br />0 <br />Change in Reading (RF - Rj): <br />0 <br />Z Pass ❑ Fail <br />0 <br />Z pass E] Fail <br />... ., ", <br />M Pass ❑ Fail <br />fn- rdad tpvtq) <br />Pass/Fail Threshold or <br />Criteria: <br />Test Result: <br />Commen-ts — (include infortnalion ott repairs fncjut�,Vt tur <br />91 Bucked failed, found leaking at Adaptor threads. Removed, cleaned. & reattached. Retested & PASSED. <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements, <br />Technician's Signature: Date: <br />State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more <br />stringent. <br />Monitoring Certification Test Report 4 of 4 <br />