My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:28:27 PM
Creation date
6/23/2020 6:51:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1997
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_1986-1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
424
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL <br />1. Provide the name and address of the facility. <br />2. Provide the name, address, and phone numbers of the contractor(s), facility <br />owner(s), and operator(s). <br />3. Provide four complete sets of plans. (One to be retained by this office). <br />Include specification sheets, equipment brochures, monitoring, and response <br />plans. <br />4. Provide plans to scale in nonerasable blueprint. <br />1. Location(s) and number of tanks. <br />2. Type of tank(s) to be installed. <br />A. Steel clad with fiberglass reinforced plastic. <br />1. 35,000 to 40,000 volt Holiday Test required before "setting" tank(s) <br />in ground. <br />B. Fiberglass <br />1. Striker plate dimensions and materials. <br />2. Striker plates under all accessible openings. <br />C. -Nonclad steel <br />.1. Cathodic protection provided (including nuts, bolts, washers, etc.). <br />a. Approved by a corrosion engineer or NAGE technician. <br />b. Document stating inspection method and frequency (Minimum semi- <br />annual inspection required). <br />D. Other types of tanks <br />1. Construction specification standards for durability. <br />3. Tank Capacity (List specific gallonage). <br />4. Contents to be stored in each tank (Be specific). <br />A. Verification of product compatability with the tank(s), piping, monitoring <br />device(s), epoxy or silicone glues, etc. <br />1. List testing organization and approval. <br />5. Provide manufacturers written installation instructions. (Include all piping, <br />monitors, tanks, etc.) <br />Note - NFPA 3.0 Test required before covering tank and systems. NFPA 30 Test <br />is required on BOTH the Primary and Secondary containment systems. <br />Double walled tanks using pressure or vacuum testing to monitor annular <br />space are exempt from testing secondary container. <br />Note - NFPA 329 "Precision Test" required upon completion of installations. <br />One test result copy to be sent directly to this department from the <br />testing company. <br />L 9 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.