Laserfiche WebLink
` AOL �J <br /> FIED PROGRAM CONSOLIDATED FO q' <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections I,11,III,IV,and IX below) 430. <br /> ❑ 1.NEW PERMIT E 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430x. I DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ 1. <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> Chevron Station #96171 <br /> BUSINESS SITE ADDRESS 103. CITY 104. <br /> 6633 Pacific Ave Stockton, CA 95207 <br /> II. TANK DESCRIPTION <br /> TANK ID# 432�� � 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> 3 k 7 XERXES ID 1.A STAND-ALONE TANK Complete one page for each <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 437, <br /> 01/01/1986 10,000 0 <br /> III. TANK USE AND CONTENTS <br /> TANK USE ® la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ Ic.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN [199.OTHER(Specify): 439a. <br /> ....................... <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ ]c.MIDGRADE UNLEADED ID lb.PREMIUM UNLEADED 440. <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑..._8.PETROLEUM BLEND FUEL............_0.._9.:._OTHER PETROLEUM(Specify):...... 440a. <br /> .............................................. <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ID 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> _............................................................... <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ID 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 4`14 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 44aa. <br /> ............................................................................................................................................_.............................................................................................................................................. <br /> ................... <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ID 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN [199.OTHER(Specify): 445a. <br /> ....................................................................................... <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ID 2.DOUBLE WALL r_199.OTHER 460. <br /> ........... ........ ... ... ...... ......................................................................................._. <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(a)(3)] 458. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 1-0--.-R**IGID PLASTIC aha. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a. <br /> ................................................................................................................................................................................................................................ ....................................................._. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ID 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> ..........................................................................................................................................__.........._................................. ........................................................ <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644. <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ® 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464el. <br /> ......................................................................................................................................................................................_....................................................................................................................................................................................................................................................................................................................... <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ID 90.NONE ❑ 99.OTHER(Specify): 6464f <br /> ......................................................................................................................................................................................................................... <br /> .................................................................................. .......... 464g. <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ID 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464 1,_____ <br /> ....... .. ... ......... ........__.................................................................................. .......... ....... - .. ....... .......................................................... <br /> . ._ (Specify): 464h1. <br /> VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ID 90.NONE ❑ 99.OTHER464h. <br /> .......................................................................................................................................................................................................................... <br /> ........................................................................................... <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ID 90.NONE 464'. <br /> ....... .......................................................................................................................................................... .............................................................:..........................................................................................................d64'...... <br /> .......................................................................................................................................................................... ............. <br /> RISER PRIMARY CONTAINMENT ID 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 664'1. <br /> ...............................................................................................................-.............................._............................................................................................................_._......................._..................... .1.......... <br /> ................................................................................................................................................................................ .. .... .. <br /> RISER SECONDARY CONTAINMENT [:11.STEEL ❑ 4.FIBERGLASS El 10.RIGID PLASTIC ID 90.NONE El 99.99.OTHER(Specify): 46641. <br /> ........................................................................-..................._................................................................................................................................................................................................................................................................................... <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ID 3.STRIKER PLATE/BOTTOM PROTECTOR ID 4.CONTAINMENT SUMP 451a-c. <br /> VII. UNDER DISPENSER CONTAINMENT (UDC) <br /> CONSTRUCTION TYPE ID 1.SINGLE WALL ❑ 2.DOUBLE WALL El 3.NO DISPENSERS [190.NONE 469a. <br /> ......................_.........._..._................................................................................................................................................................_.................................................................................................. <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ID 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469c. <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ISOLATION 448 <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accurate,and in full compliance with legal requirements. <br /> APPLICANT SIGNATURE:1FU0,WR97AEZ DATE 01/12/2009 470 <br /> APPLICANT NAME(print) Chevron Products Co./FRED MARTINEZ 471. APPLICANT TITLE Retail HES Permit Desk 472 <br /> UPCF UST-B Rev.(12/2007) <br />