Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FO r <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION tone for{ UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections I,A III,IV,and IX below) 430. <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a I DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) - - 1 <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3 <br /> Chevron Station#96171 <br /> BUSINESS SITE ADDRESS 103. 1 CITY 104. <br /> 6633 Pacific Ave Stockton, CA 95207 <br /> II. TANK DESCRIPTION <br /> TANK ID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> 1 XBRXES ® 1.A STAND-ALONE TANK Complete one page for each <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 43z <br /> 01/01/1986 10,000 0 <br /> III. TANK USE AND CONTENTS <br /> TANK USE ® la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ lc.AVIATION FUELING 432 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a. <br /> -..............__........._.._..-._......................._._._. ................._............................................_.._._......................_._ _.....-_..........................................................................................................................................._................... ....................... <br /> CONTENTS PETROLEUM: ® ]a.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑ ib.PREMIUM UNLEADED 440. <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑„-8,.PETROLEUM BLEND FUEL 0 9:OTHER PETROLEUM_(Spe!off 440a..:..........- -- <br /> ._......._.....__....._..............._......... -..__.._..__....... ..... ........................................... <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 440b. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE W_ALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> PRIMARY CONTAINIv1ENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 444a. <br /> ......................_.........................................................................-...---.....--...................................._...._............................................................................_................... ..............................................._.. <br /> SECONDARY CONTAINMENT ❑ I.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN [199.OTHER(Specify): 445a. <br /> _...__._..........._.._.........._.._.._........ ...................... <br /> ................................................................................................._....-..__..............---...._......_......_..._..._....._.._._.................... ....._................................_...__.. <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 99.OTHER 460. <br /> _.............................-_..._.....-..._........................................................................................................................................................................._......_...._........................................................_..---............._._....._...._._._........_....................... <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(ax3)] 458. <br /> ........................................_....__......................................_.................---------................................................................_... - ....................................................................... -...-...._.._....._......_......_.............-- <br /> PRIMARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a. <br /> ....................-.....__...__._._..............................._.............................................-_..............................................................._.._._-......................................-.._._..- - - _._.__-..... __......._......_.._.._........ <br /> _ <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> ...................................................... <br /> __......................._.-._.........._..__.._....._..............................................................................................................................._..---._.........__...-..__..._............. <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d. <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ® 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE [1 99.OTHER(Specify): 464el. <br /> _.-_................................................................................_......_._._.................................__........._......................._._._...............................-_._.....----............................................................................................................................................__..._.......---..._.................... <br /> ..................... <br /> VENT'SECONDARY CONTAINMENT 1--] 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90:NONE C] 99.OTHER(Specify): 4648 <br /> ............................................_.........................._..---..._... _................._............................................................................................................................................_._................................ ....................... <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): q Wig_ <br /> 464h. <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE [199.OTHER(Specify): 464h1 <br /> _.._...----... ...-_��.- -.....----.........................................................................__._............................._...__._.._.......................----..........__.............................................................................-.. . . <br /> _............._-...._.......................................................................... i.... <br /> VENT PIPING TRANSITION SUMP TYPE [11.SINGLE WALL [:12.DOUBLE WALL ® 90.NONE <br /> ............................................__._..._..._........................-_..._.........---....................._..............................---._....._..............._...._._................................................................................................................_.._........_._....._-.-._............__..................................._................................................................................................_._.4�...... <br /> RISER PRIMARY CONTAINMENT ® 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 4641..,.,., <br /> ......................................................................................................_...................................................-..........._........ _..................__.._...................................................................................................................................._........_-..... ---.................................._............................................. <br /> RISER SECONDARY CONTAINMENT [11.STEEL [14.FIBERGLASS El10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): a64k1. <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATE/BOTTOM PROTECTOR ® 4.CONTAINMENT SUMP <br /> VII. UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE 01.SINGLE WALL ® 2.DOUBLE WALL El 3.NO DISPENSERS [190.NONE 469a. <br /> ...._.._....._.._..-----...............................-----..._.............................................................................................................................. ................._......................_.---..............................................................................................................................................................._.....................................................................................69........ <br /> 4 . <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC [199.OTHER(Specify) 469c. <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certifyatthN UST system is compatible with the hazardous substance stored and that the informatio ayided herein is true, <br /> l <br /> accurate, in f com liance with legal requirements. <br /> 0. <br /> APPLICANT SIGNATURE: DATE 06/10/2009 ► 47 <br /> r. <br /> APPLICANT NAME(print) Chevron r /JIM HARTMAN 471, APPLICANT TITLE Retail HES P?!.., ' Desk 472 <br /> UPCF UST-B Rev.(12/2007) <br />