My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:49:58 PM
Creation date
6/23/2020 6:52:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> 2-hour* 420-psi <br /> 1-day 650-psi <br /> 28-day 750-psi <br /> *After Final Set. <br /> Using CONCRETE IX <br /> SURFACE PREPARATION: <br /> Where bonding is important, the adjacent surfaces shall be clean, sound and free from any materials <br /> that may inhibit bond such as oil, asphalt, curing compounds, acids, dirt and loose debris. Roughen <br /> surfaces and remove all unsound concrete. Immediately prior to placement the repair surface shall be <br /> thoroughly saturated with no standing water. <br /> MIXING: <br /> The use of a power driven mechanical mixer, such as a mortar mixer or a drill mounted mixer, is <br /> recommended. Organize work so that all personnel and equipment are in place before mixing. Use <br /> clean Potable water. Rapid Set@ CONCRETE MIX may be mixed using 3 to 5 quarts of water per 60 <br /> Ib. bag. Use less water to achieve higher strengths. Do NOT exceed 5 quarts of water per bag. For <br /> increased fluidity and workability use Rapid Set® FLOW CONTROL® plasticizing admixture from the <br /> Concrete Pharmacy®. Place the desired quantity of mix water into the mixing container. While the <br /> mixer is running add Rapid Set® CONCRETE MIX. Mix for the minimum amount of time required to <br /> achieve a lump-free, uniform consistency (usually 1 to 3 minutes). Do NOT re-temper. <br /> PLACEMENT: <br /> Rapid Set® CONCRETE MIX may be placed using traditional methods. Organize work so that all <br /> personnel and equipment are ready before placement. Place, consolidate and screed quickly to allow <br /> for maximum finishing time. Do NOT wait for bleed water, apply final finish as soon as possible. Rapid <br /> Set® CONCRETE MIX may be troweled, floated or broom finished. On flat work Do NOT install in <br /> layers, install full depth sections and progress horizontally. Do NOT install on frozen surfaces. Use a <br /> method of consolidation that eliminates air voids. To extend working time use Rapid Set® SET <br /> CONTROL® set retarding admixture. <br /> CURING: <br /> Water cure all Rapid Set® CONCRETE MIX installations. Begin curing as soon as the surface has lost <br /> its moist sheen. Keep exposed surfaces wet for a minimum of 1 hour. When experiencing extended <br /> setting times, due to cold temperature or the use of retarder, longer cure times may be required. The <br /> objective of water curing shall be to maintain a continuously wet surface until the product has <br /> achieved sufficient strength. <br /> TEMPERATURE: <br /> Warm environmental and materials temperatures will reduce the working time of CONCRETE MIX. To <br /> compensate for warm temperatures, keep material cool and use chilled mix water. Temperatures <br /> below 70OF (210C) will decrease the rate of strength gain and CONCRETE MIX should not be applied if <br /> surface or ambient temperature is below 45OF (7.20C). <br /> LIMITED WARRANTY: <br /> CTS Cement Manufacturing Corporation warrants its material to be of good quality, and, at its sole <br /> option, within one year from date of sale, will replace defective materials or refund the purchase price <br /> thereof and such replacement or refund shall be the limit of CTS's responsibility. Except for the <br /> foregoing, all warranties, express or implied including merchantability and fitness for a particular <br /> purpose are excluded. CTS shall not be liable for any consequential, incidental, or special damages <br /> arising directly or indirectly from the use of the material. <br /> CAUTION: <br /> CONCRETE MIX contains cement-itious materials and may cause irritation to lungs, eyes and skin. <br /> Avoid contact. Use only in adequate ventilation. Do NOT breath dust. Wet mixture may cause burns. <br /> Wear suitable gloves, eye protection and protective clothing. In case of skin contact, wash thoroughly <br /> with soap and water. In case of eye contact, flush immediately and repeatedly with large quantities of <br /> water and get prompt medical attention. In case of difficulty breathing, remove person to fresh air. If <br /> difficulty breathing persists, seek medical attention. <br />