COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />11 <br />MONITORING SYSTEM CERTIFICATION_9 <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, Cali rE'to"r ;,h: <br />Regulations <br />r; <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for ' L`"? r tj U 0 <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. p <br />A. General information E_NV1R0NM,,EN1!_ xt"" L"'��LT <br />Facility PACIFIC AVENUE CHEVRON <br />Site 6633 PACIFIC AVE city. <br />Y <br />Facility Contact JOSH <br />Person' <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 <br />Bldg. No. <br />STOCKTON zip: 95207 <br />Contact Phone No.: (916) 947-1277 <br />B. Inventory of Equipment Tested/Certified <br />Check the aoorooriate boxes to indicate specific eauiament inspected/serviced: <br />Date of Testing/Servicing: 1/29/2018 <br />Tank ID: 91 <br />Tank Size: <br />Tank ID: 87-1 <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />® in -Tank Gauging Probe. <br />Model: MAG -1 <br />® Annular Space or Vault Sensor. <br />Model: <br />407 <br />® Annular Space or Vault Sensor. <br />Model: 407 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />352 <br />® Piping Sump/ Trench Sensor(s). <br />Model: 352 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />PLLD <br />® Electronic Line Leak Detector, <br />Model: PLLD <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 87-2 <br />Tank Size: <br />Tank ID: <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />407 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />352 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />PLLD <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section <br />E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 34 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />DispenserlD: 5-6 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensogs). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser I D: 9-10 <br />Dispenser ID: 11-12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />Sensor(s). <br />Model: 208 <br />® Shearvalve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />`If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />\C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Ed Steams <br />Certification No.: A31048 <br />Testing Company Name: AFFORDA-TEST <br />Testing Company Address: 416 21d STREET GALT, CA 95632 <br />Signature: <br />License No: <br />Phone No. (209) 744-0113 <br />Date of Testing/Servicing: 1/29/18 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.