My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIV�b` <br />JAN 3 0 2017 Appendix Vi 40 <br />MONITORING SYSTEM CERTIFICATION <br />°� -�' For Use By All Jurisdictions Within the State of California <br />Aut './, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CRAG - PACIFIC AVE CHEVRON Bldg. No.: <br />Site Address: 6633 PACIFIC AVE. City: STOCKTON zip: 95207 <br />Facility Contact Person: CRM Contact Phone No.: 209-477.4294 <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 Date of Testing/Servicing: 1/23/2017 <br />B. Inventory of Equipment Tested/Certified <br />nL��1- a1-. � � l-�.-�� .J:..6. .. ..:di.. w r4 i wbeelrwo•liiwnla• <br />Tank ID: 91 <br />Tank Size: <br />Tank ID: 87 - 2 <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />® In -Tank Gauging Probe. <br />Model: MAG 7 <br />® Annular Space or Vault Sensor. <br />Model: <br />407 <br />® Annular Space or Vault Sensor. <br />Model: 407 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />3 5 2 <br />® Piping Sump / Trench Sensor(s). <br />Model: 3 5 2 <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />P L L D - 8 4 8 4 <br />❑ Electronic Line Leak Detector. <br />Model: SHARED W/ 87-1 <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 87 - 1 <br />Tank Size: <br />Tank ID: <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAGI <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />407 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />3 5 2 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Fiectronic Line Leak Detector. <br />Model: <br />P L L D - 8 4 8 4 <br />❑ Electronic Line Leak Detector. <br />Model: <br />0 Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: i / 2 <br />Dispenser ID: 3 / 4 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 2 0 8 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5 / 6 <br />Dispenser ID: 7 / 8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9 / 10 <br />Dispenser ID: 11 / 12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: <br />2 0 8 <br />Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />9f the facility contains more tanks or dispensers, copy mis toren. mcivae mrormauon Tor every rank anu uis�enbw ei uw IaunLy. <br />C. Certification - I certify that the equipment identified In this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: — --Z_ <br />Certification No.: A28446 License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2nd STREET GALT, CA 95632 Date of Testing/Servicing: 1/23/2017 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.