My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:54:13 PM
Creation date
6/23/2020 6:52:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
604
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nc Avenue Chevron <br />Detection of Leak into UDC Triggers Audible and Visual Alarms <br />CERS 10 <br />Pacific Avenue <br />10594654 <br />ton, CA 95207 <br />Yes <br />LIST Tank # <br />Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br />UDC Panel Model # <br />3 -Supreme <br />TLS -350 <br />UDC Monitoring Stops Flow of Product at Dispenser <br />Unleaded <br />Yes <br />Veeder Root <br />UDC Construction <br />Continuous Monitoring of Piping Secondary Containment <br />Single -walled <br />794380-208 <br />Secondary Containment Panel Manufacturer <br />Leak Sensor Manufacturer <br />Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />Veeder Root <br />Veeder Root <br />Panel Model # <br />Leak Sensor Model # <br />TLS -350 <br />794380-352 <br />Leak Alarm Triggers Automatic Pump Shutdown <br />Failure/Disconnect Triggers Pump Shutdown <br />Mechanical Line Leak Detector Performs 3 GPH Leak Test <br />Manufacturer MLLD Mode'n <br />Yes Electronic Line Leak Detector Performs 3 GPH Leak Test <br />ELLD Manufacturer ELLD Programmed In -Line Testing ELLD Triggers Automatic Pump Shutdown <br />Veeder Root Yes <br />ELLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br />PLLD Yes <br />Pipeline Integrity Testing Visual Pipeline Monitoring <br />Pipeline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br />Suction Piping Meets Exemption Criteria <br />No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected To The Tank System <br />Other Pipeline Monitoring <br />UDC Monitoring <br />Detection of Leak into UDC Triggers Audible and Visual Alarms <br />Continuous <br />Yes <br />UDC Leak Alarm Triggers Automatic Pump Shutdown <br />UDC Panel Manufacturer <br />Yes <br />Veeder Root <br />Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br />UDC Panel Model # <br />Yes <br />TLS -350 <br />UDC Monitoring Stops Flow of Product at Dispenser <br />UDC Leak Sensor Manufacturer <br />Yes <br />Veeder Root <br />UDC Construction <br />UDC Leak Sensor Model <br />Single -walled <br />794380-208 <br />UDC Secondary Containment Monitoring <br />Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br />7 <br />7"77",777777777' <br />ELD Testing <br />S Secondary Containment Testing <br />Spill Bucket Testing <br />Printed on 2/6/2015 1:45 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.