Monitoring System Certification0-ge 2 of 3 <br />Site Address: 6633 Pacific Ave <br />D. Results of Testing / Servicing <br />Software Version lnstalled• 329.02 <br />Cnmnipte thp falinwino, rhi-.eklid- <br />L] <br />Date of Testing/Servicing: 211/13 <br />H Yes <br />0 No* <br />Is the audible alarm operational? <br />H Yes <br />0 No* <br />Is the visual alarm operational? <br />19 Yes <br />El "N' o * <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />0 Yes <br />0 No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />0 Yes <br />0 No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />29 N/A <br />operational? <br />0 Yes <br />0 No* <br />For pressurized piping systems, does the turbine autornatically shut down if the piping secondary contairu-nent <br />N N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? ((;heck all that apply) Cl Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? 0 Yes 0 No <br />0 Yes <br />C. No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />X. N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 0 % <br />0 Yes* <br />0 No <br />Was any monitoring equipment replaced" If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />CiYes*_1Z <br />No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />0 Product; 0 Water. If yes, describe causes in Section E, below. <br />0 Yes <br />11 No* <br />Was monitoring system set-up reviewed to ensure proper settings? (4yach set-up reports, if applicable.) <br />0 Yes <br />0 No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />