Laserfiche WebLink
11 <br />Appendix VI <br />11 <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring <br />system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CHEVRON # 96171(N-621-1-3) Bldg. No.: <br />Site Address: 6633 PACIFIC AVE City: STOCKTON Zip: 95207 <br />Facility Contact Person: MGR - SUE LYNN <br />Make/Model of Monitoring System: Veeder Root TLS350 <br />B. Inventory of Equipment Tested/Certified <br />Contact Phone No.: 477-4294 <br />Date of Testing/Servicing: 2/1/2013 <br />Tank ID: T1 - SUPREME <br />Tank ID: regular 1 - REGULAR <br />rv, In -Tank Gauging Probe. Model: Mag <br />ry In -Tank Gauging Probe. Model: Mag <br />Annular Space or Vault Sensor. Model: 407 <br />W, Annular Space or Vault Sensor. Model: 407 <br />ry Piping Sump / Trench Sensor(s). Model: 352 <br />W Piping Sump / Trench Sensor(s). Model: 352 <br />r' Fill Sump Sensor(s). Model: 208 <br />r Fill Sump Sensor(s). Model: 208 <br />Mechanical Line Leak Detector. Model: <br />r Mechanical Line Leak Detector. Model: <br />', Electronic Line Leak Detector. Model: Veeder Root PLLD <br />', Electronic Line Leak Detector. Model: Veeder Root PLLD <br />W Tank Overfill / High -Level Sensor. Model: Flapper <br />Tank Overfill / High -Level Sensor. Model: Flapper <br />Other(specify equipment a and model in Section E on Pa e 2). <br />r Other(specify equipment a and model in Section E on Pae 2). <br />Tank ID: regular 2 - REGULAR <br />Tank ID: <br />^, In -Tank Gauging Probe. Model: Mag <br />r In -Tank Gauging Probe. Model: <br />Annular Space or Vault Sensor. Model: 407 <br />r Annular Space or Vault Sensor. Model: <br />Piping Sump / Trench Sensor(s). Model: 352 <br />r Piping Sump / Trench Sensor(s). Model: <br />Wo Fill Sump Sensor(s). Model: 208 <br />r Fill Sump Sensor(s). Model: <br />Mechanical Line Leak Detector. Model: <br />Mechanical Line Leak Detector. Model: <br />Electronic Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r'' Tank Overfill / High -Level Sensor. Model: Flapper <br />r Tank Overfill / High -Level Sensor. Model: <br />Other(specify equipment a and model in Section E on Pae 2). <br />Other(specify equipment a and model in Section E on Pae 2 . <br />Dispenser 1/2 <br />Dispenser 3/4 <br />ID: <br />ID: <br />rV Dispenser Containment Sensor(s). Model: 208 <br />Dispenser Containment Sensor(s). Model: 208 <br />r' Shear Valve(s). <br />r Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser 5/6 <br />Dispenser 7/8 <br />ID: <br />ID: <br />Dispenser Containment Sensor(s). Model: 208 <br />Dispenser Containment Sensor(s). Model: 208 <br />Shear Valve(s). <br />r1 Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser 9/10 <br />Dispenser 11/12 <br />ID: <br />ID: <br />Dispenser Containment Sensor(s). Model: 208 <br />rYO Dispenser Containment Sensor(s). Model: 208 <br />17 Shear Valve(s). <br />rvO Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information tor every tanK ana aispenser at the racurcy. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to <br />this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of <br />monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): W System set- <br />up W Alarm history report <br />Technician Name (print): Joey Mesa <br />Certification No.: A27796 <br />Testing Company Name: Tanknology <br />License. No <br />Signature: <br />.: 743160 Class'A' <br />Phone No.: (800) 800-4633 <br />Testing Company Address: 11000 N. MoPac Expressway Suite 500 Date of Testing/Servicing: 2/1/2013 <br />Monitoring System Certification Page 1 of 3 12/07 <br />