My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
34243
>
2300 - Underground Storage Tank Program
>
PR0231801
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 9:30:26 AM
Creation date
6/23/2020 6:52:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231801
PE
2361
FACILITY_ID
FA0003290
FACILITY_NAME
COUNTRY MART GAS & FOOD
STREET_NUMBER
34243
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95304-9334
APN
25318004
CURRENT_STATUS
01
SITE_LOCATION
34243 S CHRISMAN RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231801_34243 S CHRISMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION RECEIVED <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16, Division 3,Title 23,California Code ofA PR 2 �� <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for ENVIRONMENTAL <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system ,r�„$T 0�r_.r1A T�`�ENT <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test a e <br /> A. General Information <br /> Facility <br /> Name: COUNTRY MART&FOOD Bldg.No.: <br /> Site <br /> Address: 34243 S CHRISMAN RD City: TRACY Zip: 95376 <br /> Facility Contact <br /> Person: SANDHU Contact Phone No.: (209)832-8642 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 360 Date of Testing/Servicing: 04-09-18 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> TanklD: 87 TanklD: 91 <br /> N In-Tank Gauging Probe. Model: MAG 1 N In-Tank Gauging Probe. Model: MAG 1 <br /> N Annular Space or Vault Sensor. Model: 420 N Annular Space or Vault Sensor. Model: 420 <br /> N Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> N Mechanical Line Leak Detector. Model: 99 LD 2000 N Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> N Tank Overfill/High-Level Sensor. Model: FLAPPER N Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL Tank ID: DIESEL <br /> ® In-Tank Gauging Probe. Model: MAG 1 N In-Tank Gauging Probe. Model: MAG 1 <br /> IM Annular Space or Vault Sensor. Model: 420 N Annular Space or Vault Sensor. Model: 420 <br /> N Piping Sump/Trench Sensor(s). Model: 208 N Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ® Mechanical Line Leak Detector. Model: PE PETRO <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> N Tank Overfill/High-Level Sensor. Model: FLAPPER N Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> N Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> N Dispenser Containment Sensor(s). Model: 208 N Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 9-10 DispenserlD: SAT11 <br /> N Dispenser Containment <br /> N Dispenser Containment Sensor(s). Model: 208 Sensor(s). Model: 208 <br /> N ShearValve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> `If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Pian showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report. <br /> Technician Name(print): FELIX RAMIREZ Signature: t` <br /> Certification No.: 8883072-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 04-09-18 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.