Laserfiche WebLink
Ll <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />{ u.nderground S#Drage Tank Programtnspectcoln Rep®irt <br />Facility Name: <br />COUNTRY MART GAS & FOODT(209)832-8642 <br />Facility Phone: <br />Date: <br />Aril 04 2017 <br />Facility Address: <br />34243 S CHRISMAN RD TRACY CA 95304 <br />CERS ID: <br />10181085 <br />Inspection Contact: <br />Taran'it Sandhu <br />Title: <br />Owner <br />Phone: <br />209 832-8642 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For. Consent Given By: <br />® Inspection ❑x Photos x❑ Sample Taranjit Sandhu Owner <br />Service Technician Onsite: Exp. Date:Designated <br />Felix Ramirez 11/22/2018 <br />Operator: Exp. Date: <br />Felix Ramirez 02/26/2018 <br />Service Technician Manufacturer's Training: <br />VR 07/06/18; VMI 11/06/17; TT 05/31/17 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />-7777�171 <br />ale Renew <br />101 <br />HSC 25284 <br />No permit to operate <br />o V o R o COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V o R o COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V ❑ R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V o R o COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V c R o COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V ❑ R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />o V o R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V c R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V ❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />c V a R o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V ❑ R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V ❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V ❑ R o COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V o R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V o R o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V ❑ R ❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V o R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />c V ❑ R o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V o R o COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V ❑ R o COS <br />121 <br />CCR 2712(1) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V o R o COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />c V o R o COS <br />©nStWilke orcls <br />201 <br />CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />❑ V c R o COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />o V ❑ R o COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />❑ V c R ❑ COS <br />Page 1 of 4 <br />