Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Facility Name: Facility Address: <br />COUNTRY MART GAS & FOOD 34243 S CHRISMAN RD TRACY <br />Date: <br />April 04 2017 <br />;; U SysterQbservaf�ons : <br />322 HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />323 HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />324 CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />o R <br />❑ COS <br />325 CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />326 HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />o V <br />c R <br />c COS <br />327 CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />o COS <br />328 HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />329 HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />330 CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V <br />c R <br />❑ COS <br />:Single Walled Nan Presumed t?pmg <br />0, , <br />401 CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V <br />❑ R <br />c COS <br />402 CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V <br />❑ R <br />❑ COS <br />403 CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V <br />c R <br />❑ COS <br />404 CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V <br />❑ R <br />❑ COS <br />elrtalattos <br />2010 See below <br />Unlisted Administration/Documentation violation <br />❑ V <br />❑ R <br />o COS <br />2030 See below <br />Unlisted Operations/Maintenance violation <br />c V <br />❑ R <br />c COS <br />2060 See below <br />Unlisted Design/Construction violation <br />❑ V <br />o R <br />❑ COS <br />Item # I Remarks <br />306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The 87, and diesel (compartmented) grade STP sump sensor was slightly raised at an angle, and titled and not <br />located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a <br />leak at the earliest possible opportunity. The sensor was placed upright by the service technician. Ensure that all <br />monitoring equipment is maintained to detect a leak at the earliest opportunity. <br />This was corrected onsite. <br />This is a repeat violation, Class 11. <br />Page 3 of 4 <br />