My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2002-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 10:16:48 AM
Creation date
6/23/2020 6:52:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2008
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2002-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In-Tank Gauging/SIR Equipment: U Check this box if tank gauging is used only for inventory control. <br /> U Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> 21 Yes U No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> 91 Yes U No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> 21 Yes U No* Was accuracy of system product level readings tested? <br /> 0 Yes U No* Was accuracy of system water level readings tested? <br /> 0 Yes U No* Were all probes reinstalled properly? <br /> 0 Yes U No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD): U Check this box if LLDs are not installed. <br /> Complete the folio ing checklist: <br /> 91 Yes U No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br /> Ll N/A (Check all that apply) Simulated leak rate: [M 3 g.p.h.; Ll 0.1 g.p.h; U 0.2 g.p.h. <br /> 0 Yes U No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> [H] Yes U No* Was the testing apparatus properly calibrated? <br /> 0 Yes U No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> U N/A <br /> • Yes U No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> 191 N/A <br /> • Yes U No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> El N/A or disconnected? <br /> • Yes Ll No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions <br /> El N/A or fails a test? <br /> • Yes 13 No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> IF] N/A <br /> 0 Yes U No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Page 3 of 3 03101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.