My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2002-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 10:16:48 AM
Creation date
6/23/2020 6:52:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2008
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2002-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br /> UNIFIED PROGRAM (UP) FORM Q <br /> UNDERUROUND STORAGE TANKS - TAN PAGE 1 <br /> (two pages per tank) Page of ,9 <br /> TYPE OF ACTION [:]l.NEW SITE PERMIT [13.RENEWAL PERMIT ®5.CHANGE OF INFORMATION ❑TPERMANENTLY CLOSED SIT <br /> (Check one item only) ❑2.INTERIM PERMIT ❑4.AMENDED PERMIT ❑&TEMPORARY SITE CLOSURE ❑ 8.TANK REMOVED 4 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA) FACILITY ID: 1 <br /> 3JA � 0�0101310� 1(ojy <br /> UaalzCA s-�vi � Thc.. \o <br /> LOCATION WITHIN SITE(Optional) 1 <br /> I. TANK DESCRIPTION <br /> (A scaled plot plan with location(s)of UST system(s)including buildings and landmarks shall be submitted to the CUPA or PA.) Nd <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK 0 Yes ® No 434 <br /> MOCIP-^t W eldi vn Cc)- If"Yes",complete one page for each compartment. <br /> DATE INSTAL ED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 43s NUMBER OF COMPARTMENTS 437 <br /> C1 79 ZO,O®C7 I <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II. TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ❑1a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ❑1b. PREMIUM UNLEADED M 3. DIESEL ❑6. AVIATION FUEL <br /> [-12. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑3. CHEMICAL PRODUCT COMMON NAME 441 CAS# 442 <br /> (from Hazardous Materials Inventory page) (from Hazardous Materials Inventory page) <br /> ❑4. HAZARDOUS WASTE(Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK Ell. SINGLE WALL El 3. SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER <br /> ((Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN 443 <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ' r 1. BARE STEEL 3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN <br /> ((Check one item only) [32. STAINLESS STEEL 004. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER 444 <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank 1. BARE STEEL 3. FIBERGLASS/PLASTIC ❑5. CONCRETE 95. UNKNOWN <br /> ((Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS [18. FRP COMPTIBLE W/100%METHANOL[]99.OTHER 445 <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> TANK INTERIOR LINING Ej 1.RUBBER LINED 3.EPDXY LINING [15.GLASS LINING 95.UNKNOWN DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER 446 (For local use only) <br /> (Check one item only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN DATE INSTALLED 448 <br /> PROTECTION(IF APPLICABLE) PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER 448 (For local use only) <br /> (Check one item only) ❑2 SACRIFICIAL ANODE <br /> SPILL AND OVERFILL <br /> (Check all that apply) YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT YEAR INSTALLED 452 <br /> ®1 SPILL CONTAINMENT ®1 ALARM <br /> ® 2 DROP TUBE ❑2 BALL FLOAT <br /> ❑ 3 STRIKER PLATE ❑3 FILL TUBE SHUT OFF VALVE ❑4 EXEMPT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE M 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) +BIENNIAL TANK TESTING ❑99 OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCEREMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ESTIMATED DATE LAST USED(YR/MO/DAYF_�� <br /> ❑Yes ❑ No <br /> OFFICIAL USE ONLY DATE RECEIVED CUPA PA DISTRICT/INSPECTOR <br /> UP FORM(1/2000 Version) 1 UPF_LAC4:07_USTB <br /> THE CUPAs OF LOS ANGELES COUNTY <br />
The URL can be used to link to this page
Your browser does not support the video tag.