My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITMUNG SYSTEM CERTIFICCION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chdpter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate <br /> certification or report must be prepared for each monitoring system control panel by the technician <br /> who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date.A. General Information <br /> Facility Name: AT&T/SBC GEO PAR# UE-046 CLLC Code: SKTNCA1 l <br /> Site Address: 907 LINCOLN ROAD City: STOCKTON Zip: <br /> Facility Contact Person: TOM WILLIAMS Contact Phone No.: 209-466-1010 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Service: 7/18/06 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific equipment ins ected/serviced: <br /> Tank ID: 1171 Tank ID: <br /> ZIn-Tank Gauging Probe: Model: 847390-107 ❑In-Tank Gauging Probe: Model: <br /> ZAnnular Space or Vault Sensor: Model: 794390-420 ❑Annular Space or Vault Sensor Model: <br /> ZPiping Sump/Trench Sensor(s): Model: 794380-352 ❑Piping Sump/Trench Sensor(s): Model: <br /> ZFill Sump Sensor(s): Model: 794380-352 ❑Fill Sump Sensor(s): Model: <br /> []Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> []Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other,Specify a ui . e and model in Section E on Page 2 ❑Other,Specify a ui . e and model in Section E on Pa e 2 <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe: Model: ❑In-Tank Gauging Probe: Model: <br /> ❑Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: []Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> []Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: []Tank Overfill/High-level Sensor: Model: <br /> ❑Other, Specify a ui . e and model in Section E on Page 2 ❑Other,Specify SgHip.toe and model in Section E on Page 2 <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). [IShear Valve(s). <br /> ❑Dis enser Containment Floats and Chains ❑pis enser Containment Floats and Chain s <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> []Dispenser Containment Float(s)and Chains ❑Dis enser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> []Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chains ❑Dis enser Containment Float(s)and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that <br /> this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating <br /> such reports, I have also attached a copy of the report; (check all that apply): Z System set-u - m is ory <br /> report <br /> Technician Name(Print): MICHAEL L. STRAWN,II Signature: ,.` <br /> Certification No.: 006-05-3018 License No.: 88098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714)560- <br />
The URL can be used to link to this page
Your browser does not support the video tag.