My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:51:51 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
354
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PU <br /> onitorin System Ce 'ficatiose By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7, Health and Safety Code,Chapter 96,Division 3, Title 23, Califomis Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certificationor report must be prepared for each <br /> monitoring system control panel by the technician who performs the work.A copy of erns o u e prove a iii fanK System owner/operator.The <br /> owner opera or Must SUDMit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility: Pacific Bell Telephone Co. dba AT&T Califomia GEO PAR#UE046 <br /> Address: 907 LINCOLN RD. City: STOCKTON Zi : 95207 <br /> Facility Contact Person: Connie Michell Contact Phone No: <br /> Make/Model of Monitoring System:Veeder Root TLS 350 Service Date: 05/02/2 <br /> B. Inventory of Equipment Tested/Certified 1 9 200 <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: UE0460002 Tank ID: ' ` UN CV" `- <br /> AVEPERM!T <br /> ®In-Tank Gauging Probe Model:847390-104 ❑In-Tank Gauging Probe Model: <br /> ❑Annular Space or vault Sensor Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: <br /> ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector <br /> Model: <br /> ®Tank Overfill/High Level Sensor Model:350 series B1 ❑Tank Overfill/High Level Sensor Model: <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) <br /> Tank ID: Tank ID: <br /> ❑in-Tank Gauging Probe Model: ❑In-Tank Gauging Probe Model: <br /> ❑Annular Space or vault Sensor Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: <br /> ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High Level Sensor Model: ❑Tank Overfill/High Level Sensor Model: <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensors) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment WentWWd in this document was inspectediserviced in accordance the <br /> manufacturers'guidelines.Attached to this Certification is inform (e.g.manufacturers'checklists)necessary to verify <br /> that this information is correct and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of <br /> generating such reports,I have also attached a copy of the report;(check all that apply): <br /> ®System set-up ®Alarm history report <br /> Technician Name(Print):John Cascio Si nature: <br /> Certification No: 835337 License 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL Phone No: (714)560-8222 <br /> SERVICES <br /> Pagel of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.