My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:56:31 PM
Creation date
6/23/2020 6:53:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r0 <br /> Appendix VI RECEIVED <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION MAR 3 12014 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Tule 23,California Code ofRegulationENV§ ENTAL <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be I 1�^ <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner opera or. °Ylie <br /> ffm <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co. dba AT&T California Building No.: UE046 <br /> Site Address: 907 LINCOLN RD. City: Stockton Zip: 95207 <br /> Facility Contact Person: Dave Dube Contact Phone No.: (209)532-3447 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Plus Date of Testing/Servicing: 3/14/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: <br /> UE046UO02 € Tank ID: <br /> In-Tank Gauging Probe. Model: 846390-104/716086 In-Tank Gauging Probe. Model: <br /> II Annular Space or Vault Sensor. Model: 794390.420/195625 f Annular Space or Vault Sensor. Model: <br /> P Piping Sump/Trench Sensor(s). Model: 794380-208/674465 piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 794380-208/685055 Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: j <br /> FElectronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model:790091 001 Tank Overfill/High-Level Sensor. Model: <br /> 1 <br /> Other(specify equipment type and model in Section E on Page 2). r Other(specify equipment type and model in Section E on Page 2). <br /> Tank IDs Tank ID: <br /> In-Tank Gauging Probe. Model: F In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: F Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: F Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: r— Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: r— Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). F Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). r— Shear Valve(s). <br /> 1 F Dispenser Containment Float(s)and Chain(s). F Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: � Dispenser ID: <br /> F Dispenser Containment Sensor(s). Model: F Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this(form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e g.manufacturers'checklists)necessary to verify that this information is correct and <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) : P System set-up Alarm history report <br /> Technician Name(print): Dan Luck <br /> Signature: X44-oz d044440" <br /> Certification No.: B35802 License.No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 SOUTH DUPONT DRIVE ANARE NLCA92806 Date of Testing/Servicing: 3/14/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.