My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2005-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:24 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2018
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2005-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM :SETUP <br />FEB 13, 2014 <br />;=SYSTEM UNITS <br />i <br />i <br />1 : 510 Pl"l <br />U.S. <br />SYSTEM LANGUAGE <br />ENGLISH <br />:_SYSTEM DATE; T I ME FORMAT <br />MON DD Y"YY''I' HH:I°M:SS x1l <br />CHP <br />3330 N AD ART RD <br />STOCKTON 95208 <br />SHIFT TIME 1 : 6:00 AM <br />SHIFT TIME 2 DISABLED <br />SHIFT TIME 3 : DISABLED <br />S H I FT TIME 4 : DISABLED <br />TAN};: PER TST NEEDED WRN <br />DISABLED <br />TANY ANN TST NEEDED WRN <br />DISABLED <br />LINE RE—ENABLE METHOD <br />PASS LINE TEST <br />LINE PER TST NEEDED kIRN <br />DISABLED <br />LINE ANN TST NEEDED WRN <br />DISABLED <br />PRINT TC VOLUMES <br />ENABLED <br />TEMP COI°1PENSATION <br />VALUE (DEG F ): 60.0 <br />TICK HEIGHT OFFSET <br />DISABLED <br />DAYLIGHT SAVING TIME <br />DISABLED <br />SYSTEM SECURITY <br />CODE : 000000 <br />CUSTOM ALARM LABELS <br />DISABLED <br />COI°MUNICATIONS SETUP <br />FORT SETTINGS: <br />NONE FOUND <br />RS -232 END OF MESSAGE <br />DISABLED <br />I N -TANK SETUP - — <br />— — — — <br />T 1:UNLEADED <br />HIGH WATER LIMIT: <br />PRODUCT CODE <br />1 <br />THER IAL COEF'F :.000700 <br />OVERFILL LIMIT <br />TANK DIAMETER <br />96.00 <br />TANK PROFILE <br />4 FTS <br />FULL VOL <br />121408 <br />72°O INCH VOL, <br />9983 <br />48.0 INCH VOL <br />: 6204 <br />24.0 INCH VOL <br />2426 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING <br />2.5 <br />HIGH WATER LIMIT: <br />3°0 <br />MA`I, OR LABEL VOL: <br />12408 <br />OVERFILL LIMIT <br />9046 <br />11167 <br />HIGH PRODUCT <br />95's <br />11787 <br />DEL, I VERY I 1111 T <br />1545 <br />1861 <br />L,oW PRODUCT <br />1000 <br />LEAK ALARM LIMIT: <br />99 <br />SUDDEN L=ASS LI11IT: <br />99 <br />TANK TILT <br />1 ,GG <br />`PROBE OFFSET <br />0.00 <br />SIPHON I°IAN I FOLDED TANKS <br />T#: NONE <br />LINE 1'lAN I FOLDER TANKS <br />T#: NONE <br />LEAK MIN PERIODIC: U�5 <br />0 <br />LEAK MIN ANNUAI. : 0% <br />0 <br />FIER I OD I C: 'TEST TYPE <br />STANDARD <br />ANNUAL TEST FAILI�ISABLELi <br />ALARM 1 <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL � <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TA NI: TEST NOTIFY: OFF <br />TNK TST SIPHON BR&AK:OFF <br />i <br />DELIVERY DELAY 1 M I l l <br />PUMP THRESHOLD 10.00" <br />LEAK TEST METHOD <br />TEST 01-4 DATE : ALL TANI: <br />I InOL <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L I:TURBINE SUMP <br />TRI — iTATE (SINGLE FLOAT) <br />CATEGORY . STP SUMP <br />L 2:ANULAR SPACE <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 3:FILL SUMP <br />TRI—STATE (SINGLE GLE FLOAT ) <br />CATEGORY . OTHER SENSORS <br />L 4:DISPENSER PAN <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />OUTPUT—RELAY SETUP — — <br />R 1:F'UMP :SHUT OFF <br />TYPE: <br />STANDARD <br />P-JORMALLY CLOSED <br />I N—TANK ALARMS <br />ALL :HIGH WATER ALARM <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />L 4:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L. 2,.SENSOR OUT ALARM <br />L 3:SENS0R OUT ALARM <br />L. 4 : SENSOR OUT ALARM <br />L 1 'SHORT ALARM <br />L 2:SHORT ALARM <br />L 3 : SHORT ALARM <br />L 4:SHORT ALARM <br />
The URL can be used to link to this page