Laserfiche WebLink
Jan.21. 2011 2:08PM RUMEX CONSTRUCTION No -3858 P. 2/6 <br />. .1 MONARING SYSTEM CERTIFIRLTION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofIL-gulations <br />This form mw be used to document testing and servicing of monitoring equipment. A separate certification or report must ared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Stockton CHP <br />Bldg, No.: <br />Site Address: 3330 N. Ad Art Rd <br />City. Stockton Zip: 95215 <br />Facility Contact Person: Jim Murray <br />Contact Phone No.: 209) 943-8666 <br />Make/Modelof Monitoring System: VI& 7-,�y aro <br />Date of Testing/Servicing: 11101a <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to Indieste !gftific e9uil?mentGas gSS2serviced: <br />Tank ID: 87 <br />Tank ED; <br />0 In -Tank Gauging Probe. Model; Veeder Root <br />0 In -Tank Gauging Probe. Model, <br />• Annular Space or Vault Sensor, Model; Wader Root 420 <br />El Annular Space or Vault Sensor. Model: <br />• Piping Sump / Trorzh Samr(s), Model: Vender Root 208 <br />0 Piping Sump / Trench Sensor(s). Model., <br />• Fill Sump Sonsoi(s), Model: Veader Root 208 <br />0 Fill Sump Sensor(s). Model: <br />[D Mechanical Line Leak Detector. Model: FE Petro <br />0 Mechanical Line Leak Octoctor. Model; <br />0 Electronic Line Leak Detedor. Model: <br />0 Electronic Lino Leak Detector, Model; <br />* Tank Overfill / high-level Sensor. Model: FW1222r <br />0 Tank Overfill / High -Level Sensor, Model: <br />* Other (specify equipment type and model in Section E on Page 2). <br />El Other (specify equipment type and model in Section E on Page 2). <br />Tank ED: <br />Tank ID., <br />C3 In -Tank Gauging Probe. Model., <br />[I In -Tank Gauging Probe. Model: <br />n Annular Space or Vault Sensor. Model., <br />0 Annular Space or Vault Sensor. Model: <br />0 Piping Sump / Trench Sensor(s). Model: <br />0 Piping Sump / Trench Sensor(s). Model: <br />0 Fill Sump SensoKs). Model; <br />0 Fill Sump Sensor(s). Model: <br />0 Mechanical Lim Leak Detector. Model, <br />0 Mechanical Line Leak Detector. Model: <br />0 Eketromo Line Leak Detector. Modd, <br />El Electronic Line Leak Detector. Model: <br />C1 Tank Overfill / ffigh-Level Sensor. Model: <br />[I Tank Overfill / High -Level Sensor. Model! <br />[I Other (specify equipment type and model m SoctionE on Pago 2). <br />❑ Other (specify equipment W and model in Section E on Page 2). <br />Dispenser ED: 112 <br />Dispenser 11): <br />0 Dispenser Containment Sensoi(g). Model: Wader Root 208 <br />0 Dispenser Containment Scasor(s). Model; <br />0 Shear Valve(s), <br />[I shear vaive(s), <br />C1 Dispenser Containment Floats) and Chain(s). <br />❑ Dispenser Co Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />E) Dispenser Containment Sensor(s). Model: <br />El Dispenser Containment Sensor(s), Model: <br />El Shear Valvc(t). <br />[I Shear Valve(s), <br />C3 Dispenser Containment Float(s) and Chain(s). <br />0 Dispenser Contaimment Float(&) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />[) Dispenser Containment Sensor(s). Model: <br />[3 Dispenser Conzaiw= Sensor(s). Model. <br />n Shear Valve(s). <br />El Shear Valve(s), <br />0 Dispenser Containment Float(s) and Cham(s). <br />[] Dispenser Containment Float(a) and Cha*s). <br />*If the facility contains more tanks or dispensers, copy this form. Inelude information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment Identified <br />in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is Information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring <br />equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check ail Mat apply): <br />System set-up El Alarm history report <br />.1 <br />Technician Name (print): Jesus Garcla <br />sigziarm- . ..... <br />Certification No.: 8061091 -UT <br />License. .872234 <br />Testing Company Name: Rumex Construction Corp <br />Phone No.: (569) 271-3300 <br />Testing Company Address: 4670 N. Bendel Ave. Fresno, CA 93722 Date of Testing/Servicing: 1110/2011 <br />Page 1 of 3 <br />Rev (2/08) <br />