Laserfiche WebLink
0 <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited:- Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California' <br />�a ����� <br />This form must be used to document testing and servicing of monitoring equipment. A s_parate certificatior�� ® t`(`"ared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days <br />of test date. <br />A. General Information <br />Facility Name: CHP Stockton <br />Site Address: 3330 N. Ad Art Rd. <br />Facility Contact Person: Linh Ngo <br />Make/Model of Monitoring System: Veeder Root TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Phone: <br />City: <br />Stockton <br />Bldg. No. <br />Zip: 95208 <br />Date of Testing/Servicing: 2-26-10 <br />Tank ID: 87 Gasoline <br />Dispenser ID: <br />® Dispenser Containment Sensor(s). Model: 794380-208 <br />Tank ID: <br />® Shear Valve(s). <br />® In -Tank Gauging Probe. <br />Model: <br />846390-107 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />794390420 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: <br />794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />STP MLD <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />Drop Tube <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Pae 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />❑In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment a and model in Section E on Pae 2). <br />❑ Other (specify equipment a and model in Section E on Page 2). <br />Dispenser ID: 87 Gasoline <br />Dispenser ID: <br />® Dispenser Containment Sensor(s). Model: 794380-208 <br />❑ Dispenser Containment Sensor(s). Model: <br />® Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />I ❑ Dispenser Containment Float(s) and Chain(s . <br />•If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and <br />a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply): ® System set-up ® Al <br />a <br />Technician Name (print): Brian Halfwassen <br />Certification No.: A24602 <br />Testing Company Name: California Hazardous Services, Inc. <br />Site Address: 3132 W. Adams Street, Santa Ana, CA 92704 <br />rm h>story report <br />Signature: <br />License o,: 734854 <br />Phone: (714) 434-9995 <br />Date of Testing/Servicing: 2-26-10 <br />Page 1 of 3 11/06 <br />