My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2003-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
6/23/2020 6:53:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2011
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231911_14971 N HWY 88_2003-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT NG SYSTEM CERTIFICATION <br />e By All Jurisdictions Within the State of Califomi <br />Authority Cited. Chapter 6.7, H and Safety Code; Chapter 16, Division 3 Title 23, Mmia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: COUNTRY SIDE MINI MART <br />Site Address: 14971 N HWY 88 <br />Facility Contact Person: GARY BURGIN <br />Make/Model of Monitoring System:V/R TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: LODI <br />Contact Phone No: 368-5380 <br />Date of Testing/Service: 04/04/2007 <br />Work Order Number: 2248292 <br />CA Zip: 95240 <br />Tank ID: 87 <br />Tank ID: 91 <br />7 In -Tank Gauging Probe. <br />Model: MAG -1 <br />X In -Tank Gauging Probe. <br />Model: MAG -1 <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />7X Annular Space or Vault Sensor. <br />Model: 420 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />X1208 <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />�( Mechanical Line Leak Detector. <br />Model: MLD <br />Mechanical Line Leak Detector. <br />Model: FX1V <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: UbL <br />Tank ID: <br />In -Tank Gauging Probe. <br />Model: MAG -1 <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/french Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. <br />Model: FX1 DV <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: 3/4 <br />3q Dispenser Containment Sensor(s) <br />Model: 208 <br />X Dispenser Containment Sensor(s) <br />Model: 208 <br />RI Shear Valve(s). <br />—X-1 Shear Valve(s) <br />❑ Dispenser containment Float(s) and Chain(s). <br />7 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />FlDispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />" If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): ❑ System set-up X❑ Alarm history report <br />Technician Name (print): HEATH MCEVER <br />Certification No.: A27562 <br />Signature: _ <br />License. No.: <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 04/04/2007 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.