COMPLIANCE INFO_2003-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2003-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
6/23/2020 6:53:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2011
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231911_14971 N HWY 88_2003-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
p.8 <br /> Am <br /> RIFIED PROGRAM CONSOLIDATED FORMW <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONT NT(UDC)MONITORING <br /> 490-543 <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490.54b <br /> L.CONTINUOUS ELECTRONIC MONITORING ❑2.FLOAT.AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> ❑ 4.NO DISPENSERS ❑99.OTHER(.Specify). - ----------- - - -- - -- - ------------ <br /> PANEL MANUFACTURER: if - ' <br /> ---_-._-r-�__--� _ - _�MODEL#: � <br /> -- ---- _--- - - --- - --- ---------- O L.#(S) --- <br /> LEAK SENSOR MANUFACTURER: ��^ P�- - car `s S MODEL/I(S): �" 490.59 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS W a.YES ❑b.NO 490-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ,® a.YES ❑b.NO age 6° <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. f'a.YES ❑b.NO 490-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. a.YES ❑b.NO 49x62 <br /> 2.UDC CONSTRUCTION IS 1.SINGLE-WALLED ❑2.DOUBLE-WALLED 490-63 <br /> 490.64. <br /> IF DOUBLE WALLED: <br /> —UDC INTERSTITIAL SPACE IS MONITORED BY: -M l._LIQUID 2_PRESSURE ❑3_VACUUM _ - _ __-_�___-____ _--._ <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL TARMS ❑a.YES ❑b.NO 490-1,4b <br /> VII.]PERIODIC SYSTEM TESTING <br /> 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANC1iD 490-65. <br /> -t P K DETECTION(EL.D)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTH AS REQUIREq-(23 CCR_2644.1Z____--_ <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. � 493-66 <br /> 3.SPILL BUCKETS ARE TESTED A\NL"ALLY. 49x'6' <br /> VIII.RECORDKEEPIlVG- <br /> The following rnonitoring/maintenancc records are kept for this facility: <br /> Alarm logs Oso-6sa (�Visual Inspection RecorrL 49o•6sb ❑Tank integrity testing results 490-Gsc <br /> SlR testing results(and supporting doeumen.tion records). age-bad ❑ Tank gauging results(and supporting documentation records). 49acse <br /> ❑ATG Testing re Its(and supporting docum'niation records).490-W ❑ Corrosion Protection 60-day logs 490-68g <br /> Equipment maintenance and calibration recd s. 49msn <br /> IX.TRAINING <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490-693 <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> 19 THIS UNDERGROUND STORAGE T. NK MONITORING PLAN(Required)490-69b <br /> OPERATING MANUALS FOR ELEC-('RONIC MONITORING EQUIPMENT(Required)490-69c <br /> in CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 490.690 <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: -HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION'49C-69-- <br /> 0 <br /> 90-69°❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-699 <br /> [] OTHER(Specify):M69te,M69: <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> he"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually;and within 30 days of hire.This <br /> trainingNsill include,but is not limited to,the fo lowing: <br /> D Operation of the UST systems in a manni r consistent with the facility's best management practices <br /> Y The facility employee's role with regard o the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard o spills and overfills as specified in the UST Response Plan <br /> Names of contact person(s)for emergencies and monitoring alarms.490-70 <br /> XL CO : NTS/ADDITIONAL 04FORIVIATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures arc attached to this plan.49o-7t <br /> XI.PERSONNEL RESPONSIBII-ITIES <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: Of <br /> NAME ;r^ 490-m TITLE r 4'0 0- <br /> 490-74 TITLE i^ 49045 <br /> NAME t� <br /> The Designated Operator shall peffonn-a monthly visual inspection of the facility, provide a ftoWto the owner/operator, and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> Mi.OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certit,that the information provided herein is true and accurate to the lest of my knowledge. <br /> APPLICANT SIGNATURFi 490-76 DATE: `9v-77 <br /> !/ x,/17/,49 <br /> ,i v 0. A ri 12MARELf <br /> T „ 490-79 <br /> 490-78 APPLICANT TITLE: <br /> APPLICANT NAME(print)' <br /> Z 4 ' <br /> UPCF UST-D(12'2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.