My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14971
>
2300 - Underground Storage Tank Program
>
PR0231911
>
COMPLIANCE INFO_2003-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
6/23/2020 6:53:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2011
RECORD_ID
PR0231911
PE
2361
FACILITY_ID
FA0000540
FACILITY_NAME
COUNTRYSIDE LIQUORS & GAS
STREET_NUMBER
14971
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06316025
CURRENT_STATUS
01
SITE_LOCATION
14971 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231911_14971 N HWY 88_2003-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r 0 MIPIFIED PROGRAM CONSOLIDATED FORf� TANK: TA0505682 <br /> /J PR#: PR0231911 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 I FAC 4: FA0000540 <br /> 0 I tpl l VVV per tank) <br /> (two pages p <br /> TYPE OF ACTION 7' 1111 Page 2 of 7 <br /> (Check only item only) ❑ 1 NEW SITE PERMIT ❑ 4,�MFNDED PERMfI' ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT ($pcoily reason-f r kxal use only) (Spccif,reason-For local use onlc) <br /> ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: __[T <br /> COUNTRYSIDE MINI MART 3 FA0000540 PR0231911 <br /> LOCATION WITHIN SITE(optimal) 14971 N HWY 88,LODI 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 4 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes No 434 <br /> TA0505682 MODERN If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 5/23/1995 12:00:OOAM 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL ® 1 a.REGULAR UNLEADED ❑2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Petroleum Type) ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ le.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) 441 <br /> CAS#(from Hazardous Materials Inventory,page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERLSL-primary tank ❑ L BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99,OTHER <br /> TANK MATERIAL-secondary tank ❑ L BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/I00%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ®6 UNLINED ❑ 99.OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) E] 4 IMPRESSED CURRENT E] 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ❑ I SPILL CONTAINMENT 1,995.00 ❑ 1 ALARM ❑ 3 FILL TUBE SHUT OFF VAL` <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> W.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ (VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Chock one nem only) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.