My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:06:52 PM
Creation date
6/23/2020 6:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page _2_ of —8- <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: ❑ Tank Manufacturer N Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure N Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: 0 — 30" VACUUM GAUGES <br />Equipment Resolution: + / - 0.002" <br />Tank # 87 MAIN <br />Tank # 87 SYPHON <br />Tank # 91 <br />Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes N No <br />❑ Yes N No <br />❑ Yes N No <br />❑ Yes ❑ No <br />Tank Capacity: <br />12,000 <br />12,000 <br />12,000 <br />Tank Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Tank Manufacturer: <br />UNKNOWN <br />UNKNOWN <br />UNKNOWN <br />Product Stored: <br />87 <br />87 <br />91 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15 MIN <br />15 MIN <br />15 MIN <br />Test Start Time: <br />12:00 PM <br />12:20 PM <br />12:40 PM <br />Initial Reading (Rj): <br />10" <br />10" <br />10" <br />Test End Time: <br />1:00 PM <br />1:20 PM <br />1:40 PM <br />Final Reading (RF): <br />10" <br />10" <br />10" <br />Test Duration: <br />1 HR <br />1 HR <br />1 HR <br />Change in Reading (RF -R,): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />NO LOSS <br />Test Results <br />N <br />Pass ❑ Fair <br />0 <br />Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes N No ❑ NA <br />❑ Yes N No [--INA <br />❑Yes N No [:INA <br />❑Yes ❑ No [:INA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑Yes [:]No ®NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No ❑NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />SENSOR FUNCTIONALITY WAS NOT CONFIRMED. THIS PROCEDURE IS NOT A PART OF SB989 TESTING. <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />