My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:06:52 PM
Creation date
6/23/2020 6:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br />generating such reports, I have also attached a copy of the report; ® System set-up E] Alarm history report <br />Technicia <br />Certification: Veeder-Root: B36877 Level 4 <br />ICC Cert: 815215 -UT <br />8/30/12 <br />P.D. Bax 4208 <br />Sonnra CA c)S370 <br />AlitechPetr" B- <br />Ca: 623541 A -H,%7 <br />Phone: 2C 9-53 2-73 2 a <br />compliance, without Compromise <br />Fox: 249-533-2510 <br />ma IQalt-:AchpP.ttrc.com <br />vj,,fjtay.alt chpetrc.cam <br />MONITORING SYSTEM CERTIFICATION <br />A. General Information <br />Facility Name: Arco #5450 Date of Testing/Servicing: August 30, 2012 <br />Facility Address:1617 W. Fremont St., Stockton CA 95203 <br />Facility Contact Person: Karen Facility Phone: <br />209-462-1617 <br />LIA: San Joaquin County EHD;Inspector:Stacy Rivera;LIA Phone: ; LIA Fax: <br />Make/Model of Monitoring System: Veeder-Root TLS -350 LIA email; srivera@sjcehd.com <br />B. Inventory of Equipment Tested/Certified: <br />Tank ID: T1 Regular Master <br />Tank ID: T2 Regular Syphon <br />® In -Tan k Gauging Probe. Model: Mag 1 <br />®In -Tank Gauging Probe. Model: Mag 1 <br />®Annular Space Sensor. Model: 794380-409 <br />®Annular Space Sensor. Model: 794380-409 <br />®Piping Sump Sensor(s). Model: 794380-323 <br />®Piping Sump Sensor(s). Model: 794380-323 <br />®Fill Sump Sensor(s). Model: 794380-323 <br />®Fill Sump Sensor(s). Model: 794380-323 <br />®Electronic Line Leak Detector. Model: V -R PLLD <br />❑ Line Leak Detector. Model: <br />®Tank Overfill/ High -Level Sensor. Model: V -R Audible <br />®Tank Overfill / High -Level Sensor. Model: V -R Audible <br />® fills ill Bucket Tested: ®Pass ❑Fail <br />® Fills ill Bucket Tested: ❑Pass ®Fail <br />Tank ID: T3 Premium Tank <br />Tank ID: <br />® In -Tank Gauging Probe. Model: Mag Plus <br />❑ In -Tank Gauging Probe. Model: <br />®Annular Space Sensor. Model: 794380-409 <br />❑Annular Space Sensor. Model: <br />®Piping Sump Sensor(s). Model: 794380-323 <br />❑Piping Sump Sensor(s). Model: <br />®Fill Sump Sensor(s). Model: 794380-323 <br />El Fill Sump Sensor(s). Model: <br />®Electronic Line Leak Detector. Model: V -R PLLD <br />❑ Line Leak Detector. Model: <br />®Tank Overfill / High -Level Sensor. Model: V -R Audible <br />❑Tank Overfill/ High -Level Sensor. Model: <br />® Fillspill Bucket Tested: ®Pass ❑Fail <br />❑ Fillspill Bucket Tested: ❑Pass ❑Fail <br />Dispenser ID: 1&2 ® Sump: ®Dry ❑Water [—]Product <br />Dispenser ID: 3&4 N Sump` ®Dry ❑Water ❑Product <br />® Dispenser Containment Sensor(s). Model: 794380-323 <br />®,Dispenser Containment Sensor(s). Model: 794380-323 <br />® Shear Valves Functional test <br />®Shear Valves Functional test <br />Dispenser ID: 5&6 ® Sump: ®Dry ❑Water []Product <br />Dispenser ID: 7&8 Z Sump: NDry ❑Water ❑Product <br />®Dispenser Containment Sensor(s). Model: 794380-323 <br />®Dispenser Containment Sensor(s). Model: 794380-323 <br />® Shear Valve(s) (Functional test) <br />1 ® Shear Valve(s) (Functional test) <br />C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br />generating such reports, I have also attached a copy of the report; ® System set-up E] Alarm history report <br />Technicia <br />Certification: Veeder-Root: B36877 Level 4 <br />ICC Cert: 815215 -UT <br />8/30/12 <br />