Laserfiche WebLink
IL <br /> /1/4/6LTank:TA0192302 <br /> UNIFIED PROGRAM CONSOLIDATED FORM PR#:PR0231923 <br /> FAC#:FA 0003606 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page 1 of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE Oso. <br /> (Check one item only) ® 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. 1 FACILITY ID: 1 <br /> ARCO Facility#5450 F A 0 0 0 3 6 0 6 <br /> LOCATION WITHIN SITE(Optional): 1617 West Fremont Street,Stockton 431. <br /> Phone:209-462-1617 <br /> 1.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID#:Tank#2 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> TA0192302 Owens Corning If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1987/ 10 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> 11.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> ® 1. MOTOR VEHICLE FUEL ®1 a. REGULAR UNLEADED ❑2. LEADED [15. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE Gasoline 8006-61-9 <br /> (Includes Used Oil) - <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK [11. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑5. CONCRETE [195.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIDERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑ 1. BARE STEEL ®3. FIBERGLASS/PLASTIC [18. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450, TYPE 451. OVERFILL PROTECTION EQ NT: AR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT 1995 V ALARM OFF VALVE <br /> ®2.DROP TUBE unknown B OAT ❑4.EXEMPT <br /> ®3.STRIKER PLATE unknown JqV <br /> IV.TANK LEAK DETECTION' <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER [13.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSUREINFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />