My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 1:53:18 PM
Creation date
6/23/2020 6:53:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r >♦ Y <br /> ~ WIFIED PROGRAM CONSOLIDATED FCW <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- (Page I of 3) <br /> TYPE OF ACTION El1.NEW PLAN ® 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): 490-2a. <br /> FACILITY ID#(Agency Use Only) x•.' <br /> r j <br /> BUSINESS NAME(Same as Facility Name or DBA) 3. <br /> ARCO 05450 <br /> BUSINESS SITE ADDRESS 103 BUSINESS SITE CITY 104. <br /> 1617 W FREMONT STOCKTON <br /> II,. �QVIP-���T TESTING AND PREVE�IT�MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc)must be performed at the frequency specified <br /> _.by the eq_mpTent manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.[23 CCR§2632,2634,2638,26411 <br /> .... <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3a. <br /> p fy): 490-3b. <br /> 4904 <br /> ® 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634] <br /> LL, IVr TANK l'4 (ILTJfTOIIITG IS P r' ORMEI)IISING T�FOLLQING METHODS) .thaheck,l) . <br /> ® `l.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5, <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: Veeder Root 490-7. MODEL#: TLS-350 490-8. <br /> 490-9. 490-10. <br /> LEAK SENSOR MANUFACTURER: Veeder Root MODEL#(S); 794390-407 <br /> .._.-.__.._..._..__......... _._....._......__......._.._.._............_........ <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 ago-t t <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> 490-15. <br /> IN-TANK PROBE MANUFACTURER: 490-14 MODEL#(S): <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY490 17 <br /> ❑ e.OTHER(Specify): <br /> 490-18. <br /> PROGRAMMED TESTS: a.0.1gp h: l0.2gp:h: ❑ cOTHER(Specify) <br /> ...... ......._.._......_.._... -......---................_...._ _ ............ .............................._ ._ .._.__.. :_... 490-19:............. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.t] 490-20. <br /> _..... .._-_........_...._..._.........._......................_---._...................._............__....-...............___..._..-----_-..------...--................................_._.........................................................._.._......_.._...._......_............................ <br /> ............_........ <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§2645] TESTING PERIOD: E] a.36 HOURS F1 b.60 HOURS ago-21.2. <br /> 490-2 <br /> 490-23 <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 <br /> 490-24. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): . 49.01.7.2.5. <br /> _..._.......- -..... ---- -..__.._-.._....._.._.._....-..._............................_.............................................._....._..........._.._......._.._-....._._.._.-._.......__......__.................................................... <br /> 490-26 <br /> ❑ 99 OTHER(Specify) 490-27. <br /> (Check all <br /> PYPE MONITaRII G PERFORMED VSING T F�LLf)WING METIIOD.(S) that app y <br /> �_ ._�... <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23 36] SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-29 <br /> §2636] 490-30. 490-31. <br /> PANEL MANUFACTURER:Veeder Root MODEL#: TLS-350 <br /> 490-32. MODEL#(S): 794380-323(STP); 490-33. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 794380-344(Fills) <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-35 <br /> _._..._.. .._....._....._... -- .. ..._..._..._..........................._................................................._...................................................................................... <br /> ........ <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g--..p.h. LE..._._........._.._..__AK TESTS AND RESTRICTS OR SHUTS OFF 490-36 <br /> PRODUCT <br /> - <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> 490-37. 490-38 <br /> MLLD MANUFACTURER(S):Red Jacket 91 tank Ont) MODEL#(S): FXIV 91 tank only) <br /> ....._................ 7777-- - -_._ ._. _.._._.............................__............................. _..._. <br /> ® 490-39. <br /> 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 <br /> ELLD MANUFACTURER(S):Red Jacket 490-40 MODEL#(S): CPT 490-41 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2g•P•h. ❑ b.MINIMUM ANNUAL 0.1 gp•h. 49042. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-44. <br /> .__..-__.._.....-.---.....-.......................................__...__......_................_.........._........._....._._.._.. -- - ..._......._..................._.........._......................................................................................__....................._................_--...__._...........__._.. <br /> ❑ 4.PIPE INTEGRITY TESTING. 490-46 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHERS eci 49046. <br /> ( P fY) _..490.90_.._.. <br /> _......._....7777--..._ e__-_---_._._......_._._......_._..-------.................._.................._............_.__..._.............._.._..._._...._.._...__......_._____....._..._...__...-..._._._.._.....---.......---.._................_.. <br /> 490-48. <br /> ❑ 5.VISUAL PIPE MONITORING. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 49049- <br /> * <br /> Allowed for monitorinA of unburied emergencypenerator fuel pipin onI der HSC - <br /> .._._�_..-._ _........-_....._..___......_.._..__..__.._.._..._.__...._....-u...._.._ 490-50. <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§z636(a)(3)J <br /> �.�-. --__-.-- _._._....__.._.....___........._____.._.._.__ ...__.._....__._........_.__._. _...... <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-s1. <br /> - -.._.._..__.............w_.................._.........__........_...--- ._...__ -.._._--__ __..._._..._......_.._..._....._........__...... <br /> 490-52. <br /> ❑ 99.OTHER(Specify) 490-53 <br /> ` . <br /> \VLA01LA <br /> Aron OQdGO Relehire F.nvirnnmental Rervices Paee I of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.