My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 1:53:18 PM
Creation date
6/23/2020 6:53:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROVND STORAGE TANK +g <br /> MONITORING PLAN"- G <br /> r <br /> g0NITORING OF AREAS BENFATII DISPENSERS)IS PERFORMED USMTHE F()LLC`WWG METHOD(S)(Check all that applY) Msa: <br /> ® 1.CONTINUOUS ELECTRDNIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURER. -seder'Roar Ws" MODEL#: TI.,� M52. <br /> LEAK SENSOR MANUFACTURER: Yseder Root . MODEL##(u):_ 794 388-323 M54, <br /> WILL DETECTION OF A LEAK INTO THE UDC nuoc&-R AUDIBLE AND VISUAL S? 0 a.YES Q b.NO M"- <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? � a.YES [I b.NO `46. <br /> WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWNS a.YES Q b.NO m17. <br /> 0 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: M4S MODEL#(5): M59' <br /> 0 3.VISUALMONITORING DONE 0 s.DAILY 0 b_WEEKLY( fmageucyWmat) WD. <br /> ® 4.NO DISPENSERS <br /> F1 99.OTHER(Specify) tit. <br /> • <br /> ® 1.WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CDNIROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN.PER 23 CCR§2644,1,ELD 13 PE EVERY 36 MONTHS AS REQUIRED <br /> m <br /> .: st <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) Mso. <br /> 1. THIS UNDERGROUND STORAGE TANK ITORING PLAN fRequired) <br /> 2. ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT Mequired)* <br /> 3, THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as of K DtYV) <br /> 4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. Q CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6. [l STATE WATER RESOURCES CONIRM BO (SWRCB)PIlDUCATION "HANDBWK FOR TANK OWNERS -MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. 0 SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99.E] OTHER(Specify): <br /> nasi. <br /> Personnel with UST monitoring responsibilities are familiar with all of the abovedocumenU redevattt to their job duties and can access those documents when needed. <br /> ray 11112005,this facility will have a"Designated USI the upaera€ar mm adaathlistered by the International Code Council(ICC). By July 1, <br /> 2005,and annually thereafter,the "Designated UST OperaW will train beility anploym in the proper operation and maintenance of the UST systems.This training <br /> will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner co&%teut with the facility's best management practices. <br /> D The facility employee's role with regard to Ute leak debmijon equipment. <br /> A The facility employee's role with regard to spills and overfills. <br /> ➢ Whom to contact for emergencies and leak detection alams- <br /> For facility employees hired on or after My 1,2005,the initial waining will be zonducted within 30 days of the date of hire. <br /> . :: 6 <br /> Please use this section to include any additional UST system monitoring-related information(e.&,additional information required by your local agency): M85. <br /> *Monitoring systems manual maintained by contracted,licensed pump and tank technicians. <br /> Best Management Practices are maintained in the H.S.S.E.Retail Facility Programs Manual(Green Binder). <br /> *Tank Overfill Protection Type: Overfill Alarm,alarm visual and audible at tank Fill point(s)and operates alarm <br /> trigger at 90%. <br /> x _ <br /> THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEG MONT1'QRJIVG. BP WEST COAST PRODUCTS <br /> LLC IS RESPONSIBLE FOR MAINTAINING AND ALL MOI+l1TORlNt^s EQU rT. <br /> GiE1(iTIFI N.-I c aleci eln is trate and accurate to the best of any knowledge. <br /> (3 TOR REPRESENTIPdG. BATE. rust. <br /> 0 �--�` <br /> le <br /> 0 or <br /> O' R/OPERATOR NAME(print): 2- OWNERIOPERATOR TITLE: <br /> ALFRED REALI DEALER <br /> (Agency Use Only) This plan has been reviewed and. Approved Q Approved With Conditions a Disapproved j <br /> I.ocal Agency Signslure. Date. 11� <br /> Comments/Special Conditions, <br /> Arco#45450,Selshire Environmental Serviins Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.