My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 1:53:18 PM
Creation date
6/23/2020 6:53:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 0 <br /> 3. Piping Leak Detection Monitoring Equipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> Sump leak sensors connected to <br /> continuous monitoring system Veeder Root 794380-344-fill sumps <br /> Specify type: Continuous <br /> rl Discriminating 794380-323-turbine <br /> 0 Non-discriminating <br /> ❑Mechanical line leak detectors with <br /> programmed leak threshold of three <br /> gallons per hour <br /> Electronic line leak detectors with Red Jacket CPT <br /> programmed leak threshold of: Every pumping cycle <br /> El 0.1 gph 00.2 gph 03 gph <br /> ❑ Line integrity testing by: <br /> F1 Electronic line leak detector is <br /> equipped to conduct line tightness F1 Annually <br /> testing 0 Other: <br /> []Third party testing <br /> 0 Not reguired <br /> El Other(Specify): <br /> 4. Dispenser Leak Detection Monitoring Equipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> El Mechanical float in dispenser Continuous <br /> containment <br /> 0 Electronic leak sensor in dispenser <br /> containment: Veeder Root 794380-323 Continuous <br /> ❑ Discriminating <br /> Non-discriminating El Daily <br /> F1 Visual inspection El Other: <br /> ❑No under-dispenser containment <br /> ❑Other(specify): <br /> 5. Positive Shutdown Capabilities <br /> 0 System does not have positive shutdown capabilities <br /> El Individual dispenser shutdown will occur whenever release is sensed in under-dispenser containment <br /> Automatic pump shut off will occur whenever: <br /> Release is sensed in turbine sump <br /> Release is sensed in primary piping <br /> Release is sensed at dispenser <br /> Monitoring system is disconnected or fails in any way(fail safe) <br /> n Other(specify): <br /> 6.Secondary Containment Testing <br /> ❑Secondary containment is not tested <br /> In the State of California,secondary containment systems installed on or after January 1,2001,shall be tested upon installation, <br /> six months after installation,and every 36 months thereafter. Secondary containment systems installed prior to January 1,2001, <br /> shall be tested by January 1,2003,and every 36 months thereafter. <br /> 7. Annual Equipment Certificationrresting <br /> Annually <br /> ❑Other city): <br /> 2 <br />