FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Up <br /> Line Leak Detector Test Data Sheet <br /> Station##5450 Date 10/3/ 2008 <br /> Address 1617 W. Freemont St. <br /> Stockton, Ca <br /> Test Information <br /> 1 2 3 4 5 <br /> Product 87 91 <br /> Manufacturer Red Jacket Red Jacket <br /> Model CPT FX 1 V <br /> Full Operating Pressure(psi) 34 33 <br /> Line Bleed Back(ml) 76 148 <br /> Trip Time(sec) N/A 2 <br /> E <br /> Metering Pressure(psi) N/A 13 <br /> F/E Holding Pressure(psi) 23 26 <br /> 1 <br /> Test Leak Rate (ml/min)(gph) 189/3GPH 189/3GPH <br /> PASS or FAIL Pass Pass <br /> Comments: 91 CPT leak detection turned off to enable use of variable <br /> speed turbine. CPT failed in previous years,no parts.There mechanical i <br /> LD installation. <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility . <br /> according to the equipment manufacturers procedures and limitations and the results as listed are to my <br /> knowledge true and correct. The mechanical leak test detector test pass/fail is determined using a low <br /> flow threshold trip rate of 3 gph at 10 PSI. <br /> i <br /> Inspected By: Contractor_Tait Environmental Services <br /> Technician Dra an Pesic Lic#5240928-UT <br /> Signature •��°-C . <br />