My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:05:50 PM
Creation date
6/23/2020 6:54:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:WWW.sJ_goy.orq/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 09/01/11 <br /> Facility Address: 1617 W. Fremont St., Stockton Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> ROUTINE ANNUAL INSPECTION & MONITORING SYSTEM CERTIFICATION <br /> Violations: (32) <br /> 32. The 87 slave tank ATG probe and float were replaced on December 14, 2010 and a permit was not <br /> obtained from the EHD. The ATGs are used as the facility's overfill prevention system. Emergency <br /> repairs relating to UST system monitoring and release detection may be performed by a properly <br /> licensed, trained, and certified contractor pursuant to the EHD's policy and a permit obtained within one <br /> business day from the EHD. All other repairs must have a permit submitted to and approved by the <br /> EHD prior to beginning work. Immediately obtain a permit from the EHD for the 87 slave tank ATG <br /> probe and float. A "Failure to Obtain a Permit" penalty applies. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by October 1, 2011 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> NOTE: The technician on site did not have a certification to test the Red Jacket CPT leak detection <br /> system. This test is currently incomplete. A reinspection will be necessary to verify the functionality of <br /> the 87 leak detector. A EHD staff time associated with the reinspection will be billed at the current <br /> hourly rate ($125). <br /> NOTE: The 91 Red Jacket MLLD was tested using a FasTech leak detector tester with proper technician <br /> certifications. <br /> NOTE: The 87 slave and 91 spill buckets did not pass the initial hydrostatic testing. The technicians <br /> cleaned the drain valves. The spill buckets were retested and passed. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS BJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD Inspector. � Receiv I <br /> EHD 23-02-003Rev 0711 11 U CONTINUATION FORM <br />
The URL can be used to link to this page