My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:05:50 PM
Creation date
6/23/2020 6:54:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bp <br /> 01 <br /> v <br /> LINE LEAK DETECTOR TEST <br /> Facility : Arco 5450 Date: 09/23/10 <br /> Address: 1617 W Fremont St. <br /> City, State: Stockton, CA 95203 <br /> Testing Information <br /> 1 2 3 4 5 <br /> Product: 87 Main 91 <br /> Manufacturer Red Jacket VR <br /> Leak Detector Serial Number un readable unreadable <br /> Leak Detector Model No. CPT FXIV <br /> Full Operating Pressure (psi): 35 38 <br /> Test Leak Rate(ml/min)(gph) 3.00 3.00 <br /> Bleed Back Rate(ml): <br /> Turbine Holding Pressure (psi): 21 22 <br /> Metering Pressure(mechanical only): 10 <br /> Open/Trip Time(mechanical only): 1 min. <br /> Pass/Fail Pass Pass <br /> Comments: 87 main has an Electronic and 91 has a Mechanical. <br /> Note: Pass= Leak detector reads leak and meters line. <br /> Fail= Leak detector did not read leak. <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br /> manufacturers procedures and limitations and the results as listed are to my knowledge true and correct.The mechanical leak test <br /> detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> Inspected By: Contractor Wayne Perry 30 Main Ave Sacramento CA <br /> Technician: Brandon Smith Lic#: 300345 <br /> Signature: 'C`•� <br />
The URL can be used to link to this page
Your browser does not support the video tag.