My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:05:50 PM
Creation date
6/23/2020 6:54:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1� <br />by <br />Facility #: Arco 5450 <br />Address: 1617 W Fremont St. <br />City, State: Stockton, CA 95203 <br />Date: 09/23/10 <br />Testing Information <br />Comments: 87 main has an Electronic and 91 has a Mechanical. <br />Note: Pass = Leak detector reads leak and meters line. <br />Fail = Leak detector did not read leak. <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br />manufacturers procedures and limitations and the results as listed are to my knowledge true and correct. The mechanical leak test <br />detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Wayne Perry 30 Main Ave Sacramento, CA <br />Technician: Brandon Smith Lic#: 300345 <br />Signature:.. <br />1 <br />2 <br />3 <br />4 <br />5 <br />Product: <br />Manufacturer <br />Leak Detector Serial Number <br />Leak Detector Model No. <br />Full Operating Pressure (psi): <br />Test Leak Rate (ml/min)(gph) <br />Bleed Back Rate (ml): <br />Turbine Holding Pressure (psi): <br />Metering Pressure (mechanical only): <br />Open/ Trip Time (mechanical only): <br />Pass / Fail <br />87 Main <br />91 <br />Red Jacket <br />VR <br />un readable <br />un readable <br />CPT <br />FXIV <br />35 <br />38 <br />3.00 <br />3.00 <br />21 <br />22 <br />10 <br />1 min. <br />Pass <br />Pass <br />Comments: 87 main has an Electronic and 91 has a Mechanical. <br />Note: Pass = Leak detector reads leak and meters line. <br />Fail = Leak detector did not read leak. <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br />manufacturers procedures and limitations and the results as listed are to my knowledge true and correct. The mechanical leak test <br />detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Wayne Perry 30 Main Ave Sacramento, CA <br />Technician: Brandon Smith Lic#: 300345 <br />Signature:.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.