My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:05:50 PM
Creation date
6/23/2020 6:54:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONI NG SYSTEM CETIFI TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco BP 5450 Bldg.No.: <br /> Site Address: 1617 W. Fremont City: Stockton Zip: 95203 <br /> Facility Contact Person: Not Reported Contact Phone No.: (209) 462-1617 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 9/1/2011 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 main Tank ID: 87 aux <br /> ®In-Tank Gauging Probe. Model: mag probe ®In-Tank Gauging Probe. Model: mag probe plus <br /> ®Annular Space or Vault Sensor. Model: 409 ®Annular Space or Vault Sensor. Model: 409 <br /> ®Piping Sump/Trench Sensor(s). Model: 323 ®Piping Sump/Trench Sensor(s). Model: 323 <br /> ®Fill Sump Sensor(s). Model: 323 ®Fill Sump Sensor(s). Model: 323 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: cpt ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: probe ®Tank Overfill/High-Level Sensor. Model: probe <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 91 Tank ID: <br /> ®In-Tank Gauging Probe. Model: mag probe plus ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 409 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 323 ❑Piping Sump/Trench Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model: 323 ❑Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: red jacket FXIV ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: probe ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s). Model: 323 ®Dispenser Containment Sensor(s). Model: 323 <br /> ®Shear Valve(s).opw-2 ®Shear Valve(s).opw-2 <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> ®Dispenser Containment Sensor(s). Model: 323 ®Dispenser Containment Sensor(s). Model: 323 <br /> ®Shear Valve(s).opw-2 ®Shear Valve(s).opw-2 <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ® System set-up ®Alarm history report <br /> Technician Name(print): Omar Ruiz Signature: 01 <br /> Certification No.: B35686 License.No.: 794519-A HAZ C21 <br /> Testing Company Name: Fueling &Service Tech., Inc. (FASTECH) Phone No.:(714) 523-0194 <br /> Site Address: 7050 Village Drive, Suite D, Buena Park, CA 90621 Date of Testing/Servicing: 9/1/2011 <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.