My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4111111111h A <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 05450 1617 W FREMONT ST STOCKTON July 28 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan of all three tanks listed the <br /> UDC monitoring leak sensor model as 323, but verified on site during the inspection that the sensor is a 208. The <br /> monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br /> CERS, make the necessary changes, and retain an updated copy of the monitoring plan on site. <br /> The response plan is not current and/or not approved by the EHD. The response plan on site lacked the locations of <br /> spill control equipments and a date of when the response plan was signed by Sarah Samuel. The response plan must <br /> be uploaded to the California Environmental Reporting System(CERS). Immediately log into CERS, upload the <br /> completed form, and submit for review by the EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 326 CCR 2635(b)(2) Overfill prevention system not present, was overridden, or failed to meet overfill requirements. <br /> The external audio alarm used as part of the overfill prevention system is not currently functional on the automatic tank <br /> gauge (ATG) of USTs during the time of inspection. Observed the external visual alarm, but did not hear the audio <br /> alarm of the ATG. The service technician cleaned the wire connector, retested the ATG and it passed. Both external <br /> audible and visual alarms were observed for the ATG. This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by August 27, 2014 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Notes: <br /> Conducted a routine and Monitoring system certification with the presence of Belshire representative, Laura <br /> Gomez. Permission to inspect, photograph and take sample if necessary by Dilkaran Kalirai, owner. He left at the <br /> beginning of the inspection and instructed to give the inspection report to the cashier. <br /> Testings of the 87 and 91 line leak detectors were not conducted due to an expired calibrated equipment. The VMI <br /> line leak detector box had a calibration sticker listed as 6/3/13, which is only valid until 6/3/15. The annual line leak <br /> detector must be tested on or before August 5, 2015 to satisfy CCR 2638 (a). Informed technician that since the <br /> Received by Inspector: Phone: Date: <br /> (initial): CINDY VO, EH Specialist (209)468-8257 07/28/2015 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.