Laserfiche WebLink
Girua-RYAN IHC. <br />Appendix Vi <br />ft, Job # 10-062101 <br />MONITORING STEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited., Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General information <br />Facility Name: Arco 5450 Bldg. No.: <br />Site Address: 1617 W Fremont City Stockton zip: <br />Facility Contact Person: Contact Phone No.: <br />Make/Model of Monitoring System: VR TLS35OR Date of Testing/Servicing: 9/12/2014 <br />B. Inventory of Equipment Tested/Certified <br />' If the facility contains more tanks or dispensers, copy this form. include Information for every tank and dispenser at the facility. <br />C. Certification . I certify that the equipment Identified in this document was Inspected/serviced In accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this Information Is correct <br />and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Chris SanN(eoias Signature: <br />Certification No.: 833787 <br />Testing Company Name: <br />License. No.: 220793 <br />Gettler-Ryan Inc. Phone No.: 925-551-7555 <br />Testing Company Address: 6805 Blatta Court Suite G., Dublin, CA 94568 Date of Testing/S fECEWEwb- <br />Mooltoring <br />System Certification Page 1 of 4 12107 <br />t � k <br />%.necx the appropnerle coxes zo moicam Specmc <br />ur mene ms <br />cceorservrcea: <br />Tank 10: 1-87 <br />Tank ID: 247 <br />m <br />In -Tank Gauging Probe. <br />Model: <br />847390107 <br />® <br />In -Tank Gauging Prole. <br />Model: <br />846380-107 <br />❑ <br />Annular Space or Vault Sensor. <br />Madel: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />© <br />Piping Sump /Trench Sensor(s). <br />Model: <br />794386 208 <br />® <br />Piping Sump/ Trench Sensor(s). <br />Model: <br />794380208 <br />® <br />Fill Sump Sensor(s). <br />Model: <br />7 <br />® <br />Fill Sump Sensor(s). <br />Model: <br />794380-344 <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />® <br />Electronic Line Leak Detector <br />Model: <br />8484-80 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />L13 <br />Tank Overfill / High -Level Sensor. <br />Model: <br />® <br />Tank Overfill / High -Level Sensor. <br />Model; <br />VR <br />❑ <br />Others ui ment and model <br />in Section E on Pae 2). <br />❑ <br />Other(specifyul ment a and model in Section <br />Tank ID: 3-91 <br />Tank 10: <br />© <br />in -Tank Gauging Probe. <br />Model: <br />846390-107 <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />® <br />Piping Sump / Trench Sensor(s). <br />Model: <br />794380208 <br />❑ <br />Piping Sump / Trench Sensor(s). <br />Model: <br />® <br />Fill Sump Sensor(s). <br />Model: <br />784380.344 <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />® <br />Electronic Line Leak Detector <br />Model: <br />114= <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />® <br />Tank Overfill / High -Level Sensor. <br />Model: <br />VR <br />❑ <br />Tank Overfill! High -Level Sensor. <br />Madel: <br />❑ <br />Other (Necify equipment We and model in Section E on Pae 2). <br />❑ <br />other (specify equipment and model in Section E on Pa e 2 . <br />DispenserID: 1-2 <br />DlspermeriD: 3-4 <br />® <br />Dispenser Containment Sensor(s). <br />Model: <br />794380208 <br />12 <br />Dispenser Containment Sensor(s). <br />Model: <br />794380208 <br />® <br />Shear Valve(s). <br />® <br />Shear Valve(s). <br />❑ <br />Dispenser Containment Floes and Chain(s <br />. <br />❑ <br />Dispenser Containment Fba s and Chains . <br />Disperser ID: 5-6 <br />Dispenser ID: 7.8 <br />® <br />Dispenser Containment Sensor(s). <br />Model: <br />794380208 <br />IN <br />Dispenser Containment Sensor(s). <br />Model: <br />794380208 <br />IM <br />Shear Valve(s). <br />IM <br />Shear Valve(s). <br />❑ <br />Dispenser Containment Floa s and Chain(s). <br />❑ <br />Dispenser Containment Floaqsj and Chain(s). <br />nser ID: <br />Dispenser ID: <br />[[3 <br />Dispenser Containment Sensor(s). <br />Model: <br />E3Dispenser <br />Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />E3Shear <br />Vaive(s).Dispenser <br />Containment Float(s)and Chain(s). <br />13 <br />Dispenser Containment Fkta s and Chain(s). <br />' If the facility contains more tanks or dispensers, copy this form. include Information for every tank and dispenser at the facility. <br />C. Certification . I certify that the equipment Identified in this document was Inspected/serviced In accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this Information Is correct <br />and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Chris SanN(eoias Signature: <br />Certification No.: 833787 <br />Testing Company Name: <br />License. No.: 220793 <br />Gettler-Ryan Inc. Phone No.: 925-551-7555 <br />Testing Company Address: 6805 Blatta Court Suite G., Dublin, CA 94568 Date of Testing/S fECEWEwb- <br />Mooltoring <br />System Certification Page 1 of 4 12107 <br />t � k <br />