Laserfiche WebLink
-RECEIVER SETUP : <br />D 1:JMM <br />C213 <br />RCVR TYPE: COMPUTER <br />PORT NO: 3 <br />RETRY NO: 3 <br />RETRY DELAY: 3 <br />CONFIRMATION REPORT: OFF <br />AUTO DIAL TIME SETUP: <br />D 1 : JPiN <br />DIAL ON DATE <br />SEP 12, 2014 <br />DIAL TIME : DISABLED <br />RECEIVER REPORTS: <br />SYSTEM STATUS <br />IPJ -TANK STATUS <br />INVENTORY <br />RS -232 END OF MESSAGE <br />DISABLED <br />AUTO DIAL ALARM SETUP <br />D I: JMP9 <br />I Pl-TANK ALARMS <br />ALL:LEAK. ALARM <br />ALL:HIGH WATER ALARM <br />ALL:OVERFILL ALARM <br />ALL:LOW PRODUCT ALARM <br />ALL:SUDDEN LOSS ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:INVALID FUEL LEVEL <br />ALL:PROBE OUT <br />ALL:HIGH WATER WARNING <br />ALL : DELI +.VER �' NEEDED <br />ALL:MAi, PRODUCT ALARM <br />ALL:GROSS TEST FAIL <br />ALL:PERIODIC TEST FAIL <br />ALL:ANNUAL TEST FAIL <br />ALL:PER TST NEEDED WRN <br />ALL:ANN TST NEEDED WRN <br />ALL:PER TST NEEDED ALM <br />ALL:ANN TST NEEDED ALM <br />ALL:TANK TEST ACTIVE <br />ALL : NO C'SLD IDLE TIME <br />ALL:TANK SIPHON BREAK <br />ALL:CSLD INCR RATE WARN <br />ALL:AC'CU_CHART CAL WARN <br />ALL:RECON WARNING <br />ALL:RECON ALARM <br />ALL:LOW TEMP WARNING <br />ALL:MISSING TICKET WARN <br />ALL:GROSS FAIL LINE TNK <br />ALL:DELIVY LIENSITY WARN <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID ALARM <br />ALL:LIQUID WARNING <br />WIRE CL ALARMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID ALARM <br />ALL:LIQUID WARNING <br />COMM SIDE DIM ALM <br />ALL:DISABLED DIM ALARM <br />ALL : COMMUN I CATION ALARM <br />ALL:TRANACTION ALARM <br />RECONCILIATION ALM <br />ALL:P'ROD THRESHOLD ALM <br />ALL:CLOSE SHIFT WARNING <br />ALL:CLOSE DAILY WARNING <br />PRESSURE LINE LEAK <br />ALL:GROSS LINE FAIL <br />ALL:ANNUAL LINE FAIL <br />ALL:PER TST NEEDED WRN <br />ALL:PER TST NEEDED ALM <br />ALL:PLLD OPEN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:P'LLD SHUTDOWN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:PERIODIC LINE FAIL <br />ALL:ANN TST NEEDED WRN <br />ALL:ANN TST NEEDED ALM <br />ALL:LOW PRESSURE ALARM <br />ALL:UNKNOWN ALARM <br />ALL:CONT HANDLE ALM <br />ALL:FUEL OUT <br />ALL:LN EQUIP FAULT ALM <br />SMARTSENS0R ALARMS <br />ALL:SETUP DATA WARNING <br />ALL:COt°MUNICATION ALARM <br />ALL:SENSOR FAULT ALARM <br />ALL:FUEL WARNING <br />ALL:FUEL ALARM <br />ALL:WATER WARNING <br />ALL:WATER ALARM <br />ALL:HIGH LIQUID WARNING <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID WARNING <br />ALL:LOW LIQUID ALARM <br />ALL : TEMPERATURE WARNING <br />ALL:RELAY ACTIVE <br />ALL:INSTALL ALARM <br />ALL:SENSOR FAULT WARN <br />ALL:VA000M WARNING <br />ALL:NO VACUUM ALARM <br />ISD SITE ALARMS <br />ISD STAGE I WARN <br />ISD GROSS PRES WARN <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES WARN <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK WARN <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES WARN <br />ISD VP PRES FAIL <br />ISD VP STATUS WARN <br />ISD VP STATUS FAIL <br />MISSING RELAY SETUP <br />MISSING HOSE SETUP <br />MISSING TANK SETUP <br />MISS VAPOR FLOW MTR <br />t°MISS VAPOR PRES SEN <br />MISSING VP INPUT <br />ISD SETUP WARN <br />ISD SETUP FAIL <br />ISD SENSOR OUT WARN <br />ISD SENSOR OUT FAIL <br />PC: -ISD FAILURE <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT WARN <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT WARN <br />ALL : FLObJ COLLECT FAIL <br />ALL:AIRFLOW MTR SETUP <br />VAPOR FLW MTR ALMS <br />ALL:CHK. VAPOR FLOW MTR <br />PMC: ALARMS <br />VP RUNTIME FAULT <br />VP EMISSIONS WARN <br />VP EMISSIONS FAIL <br />VP PRESSURE WARN <br />VP PRESSURE FAIL <br />VP DUTY CYCLE WARN <br />VP DUTY CYCLE FAIL <br />PMC SETUP FAIL <br />IN -TANK SETUP <br />T 1:UNLEADED R As <br />PRODUCT <br />CODE <br />1 <br />THERMAL <br />C'OEFF <br />:.000700 <br />TANK. DIAL°METER <br />92.00 <br />TANK PROFILE <br />20 PTS <br />FULL <br />VOL <br />11627 <br />87.4 <br />INCH <br />VOL <br />11422 <br />82.8 <br />INCH <br />VOL <br />11066 <br />7:8.2 <br />INCH <br />VOL <br />10600 <br />73.6 <br />INCH <br />VOL <br />10049 <br />69.0 <br />INCH <br />VOL <br />9438 <br />64.4 <br />INCH <br />VOL <br />8774 <br />59.8 <br />INCH <br />VOL <br />8089 <br />55.':' <br />INCH <br />VOL <br />7352 <br />50.6 <br />INCH <br />''VOL <br />6591 <br />46.0 <br />INCH <br />VOL <br />5814 <br />41.4 <br />INCH <br />VOL <br />5036 <br />36.8 <br />INCH <br />VOL <br />4296 <br />32.2 <br />INCCH <br />VOL <br />3538 <br />27.6 <br />INCH <br />VOL <br />2853 <br />23.0 <br />INCH <br />VOL <br />2190 <br />18.4 <br />INCH <br />VOL <br />1578 <br />13.8 <br />INCH <br />VOL <br />1042 <br />9.2 <br />INCH <br />VOL <br />573 <br />4.6 <br />INCH <br />VOL <br />205 <br />METER DATA <br />NO <br />FLOAT SIZE: 2.0 IN. <br />WATER WARNING 2.0 <br />HIGH WATER LIMIT: 2.5 <br />WATER ALARM FILTER: LOW <br />MAX OR LABEL VOL: 11627 <br />OVERFILL LIMIT 90% <br />10464 <br />HIGH PRODUCT 95% <br />11045 <br />DELIVER;' LIMIT 15% <br />1744 <br />