My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility <br /># <br />C1 <br />C2 <br />Facility <br />U <br />I Code Section HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Inspection <br />J <br />Name: <br />Address: "4 <br />y, <br />�'. <br />Date: t <br />FacilityTitle: <br />F w <br />.'".n.: <br />101 <br />\ <br />HSC 25284 No permit to operate <br />Phone: <br />Contact: �Inl <br />V <br />HSC 25404.5 Annual operating fees not paid <br />103 <br />VIE <br />Inspection <br />Type: <br />outine <br />L onitoring System Certification ❑ Installation L Complaint - ID#: <br />❑ Other: <br />(Authority HSq <br />25289) <br />104 <br />Consent for: ` <br />nspection <br />ampling otos <br />Granted by: )iW&AJU <br />Title: Ulf, (h4 <br />Monitoring <br />Panel: <br />1Piping <br />System: <br />ressurized 7 Suction .: Gravity <br />Overfill <br />Prevention: <br />-, Mechanical - Bible/visual <br />UST <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 <br />CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />- Product--- <br />-- - - <br />- - <br />- - - - - <br />--- - <br />-------------------------------- <br />------------- <br />------------- <br />-------------- <br />- - <br />- - - - - <br />- - - - - - <br />- - - - - - - <br />Designated <br />re lacement, calibration, or certification <br />ICC Exp. <br />Operator: <br />111 <br />Date: <br />Violations: ❑ M1 -Release Detection <br />7 M2 -Release Prevention D M3 - Both <br />On Site Service , <br />` <br />ICC Exp. <br />Manufacturer's <br />113 <br />Technician: <br />N I& <br />Date: <br />Training: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />I Code Section HSC = California Health and Safety Code; CCR = California Code of Regulations <br />♦ C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />�.. <br />y, <br />�'. <br />F w <br />.'".n.: <br />101 <br />HSC 25284 No permit to operate <br />102 <br />HSC 25404.5 Annual operating fees not paid <br />103 <br />HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 <br />HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 <br />CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 <br />CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 <br />CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 <br />CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />re lacement, calibration, or certification <br />110 <br />HSC 25291(f) Annual line leak detector test not performed (M1) <br />111 <br />HSC 25284.2 Annual spill containment testing not performed <br />112 <br />CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 <br />CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 <br />CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />115 <br />CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 <br />HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 <br />CCR 2661 Permit to repair UST system not obtained <br />118 <br />HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 <br />HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 <br />HSC 25298(c) Permit to close UST system not obtained <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />201 <br />CCR 2712(b) upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />CCR 2712(i) Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />203 <br />CCR 2650 was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />
The URL can be used to link to this page
Your browser does not support the video tag.