Laserfiche WebLink
WOOLSEY OIL, INC. <br /> WKA No. 3934.01 <br /> September 29, 1998 <br /> Page 2 <br /> • selected soil samples will be stored in an ice chest containing ice and submitted under <br /> chain-of-custody documentation to a California-certified laboratory for analysis of <br /> Total Petroleum Hydrocarbons (TPH) as gasoline and diesel using modified EPA <br /> Method 8015,as well as Benzene, Toluene, Ethylbenzene, Xylenes (BTFY) and fuel <br /> oxygenates using EPA Method 8260 <br /> • backfilling soil borings to surface grade with cement grout in accordance with <br /> SJCPHSD requirements <br /> • upon completion of our field work,preparing a report of findings which will <br /> include: a site plan showing locations of soil borings, logs of borings describing <br /> soil types, laboratory test results with chain-of-custody documentation, a <br /> discussion of our findings, as well as conclusions and recommendations for <br /> additional work, if necessary. <br /> All work will be completed in accordance with the attached field procedures. If you have any <br /> questions with regard to this Workplan,please do not hesitate to call. <br /> Wallace-Kuhl&Associates,Inc. <br /> K M.Balasek <br /> S nior Hydrogeologist <br /> KMB:sdm <br /> r <br /> WALLACE•KUHL <br /> Er ASSOCIATES INC. <br />