COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2022 4:24:09 PM
Creation date
6/23/2020 6:54:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> RE: <br /> The underground storage tanks located at the above referenced <br /> facility have been interior lined. In order for the tank system <br /> to remain in compliance with this Department and the State Water <br /> Resources Control Board, there are some requirements that need to <br /> be met by the tank owner. The tank owner must comply with Title <br /> 23 CCR Section # 2663 (h) 1-9 (provided below) . <br /> (h) If a steel tank is lined for the purpose of satisfying the requirements of section 2662(c), <br /> or if any tank is repaired using the interior lining method, it shall be inspected by a coatings <br /> expert or special inspector within ten years of lining and every five years thereafter. Written <br /> certification of the inspection shall be provided by the tank owner and the party performing the <br /> inspection to the local agency within 30 calendar days of completion of the inspection. The <br /> inspection shall include all of the following: <br /> (1) Determining that the tank has been cleaned so that no residue remains on the tank <br /> walls. <br /> (2) Determining that the tank has been vacuum tested at a vacuum of 5.3 inches of Hg for <br /> no less than one minute. This vacuum test is not required if the tank is constructed of <br /> fiberglass and is submerged in groundwater by more than 50� of its depth. <br /> (3) If the tank is constructed of fiberglass, taking interior diameter measurements to <br /> verify whether the cross-section has compressed by more than one percent of the original <br /> diameter. <br /> (4) Visually checking the tank interior and lining for discontinuity,compression, tension <br /> cracking, and corrosion. <br /> (5) For steel tanks, testing the entire tank interior using a thickness gauge on a <br /> one-foot grid pattern with metal wall thickness recorded on a form that identifies <br /> the location of each reading in order to verify that average metal thickness is greater <br /> than 75 percent of the original wall thickness. <br /> (6) Testing for thickness and hardness of the lining in accordance with nationally <br /> recognized industry codes to verify that the lining meets the standards under which <br /> the lining was applied. <br /> (7) For steel tanks, testing the lining using an electrical resistance holiday detector in <br /> accordance with nationally-recognized industry codes. The owner or operator shall have <br /> all holidays repaired and checked in accordance with nationally recognized <br /> industry codes. <br /> (8) Certification from the special inspector or coatings expert that: <br /> (A) the tank is suitable for continued use for a minimum of five years. <br /> (B) the tank is suitable for continued use for a minimum of five years only if it <br /> is relined or other improvements are made. <br /> (C) the tank is no longer suitable for continued use and shall be closed <br /> in accordance with Article 7. <br /> (9) A lined tank shall be closed in accordance with Article 7 at the end <br /> of its operational life. <br />
The URL can be used to link to this page
Your browser does not support the video tag.