My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_1999-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 2:19:55 PM
Creation date
6/23/2020 6:54:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2007
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_1999-2007.tif
标签
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONIT ING SYSTEM CEI CATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitorings, stem control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: SOUTH BAY TIRE Bldg, No.: <br /> Site Address: 5101 W. CHARTER WAY City: STOCKTON Zip: 95206 <br /> Facility Contact Person: MIKE ELIASON Contact Phone No.: (209) 948-9412 <br /> Make/Model of Monitoring System: INCON TS100 Date of Testing/Servicing JUNE 21, 2007 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a uiment inspected/serviced <br /> Tank ID: REGULAR Tank ID: <br /> Z In-Tank Gauging Probe. Model: MAG ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Motel:FLOAT ❑Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s), Model:FLOAT ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: STP-MLD ❑Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model: FLOAT ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specifX e ui ment ty2e and model in Section Eon Pa e 2 . ❑Other(specify equipment e and model in Section E on Pae 2). <br /> Tank ID:DIESEL Tank ID: <br /> Z In-Tank Gauging Probe. Model: MAG ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor, Model: FLOAT ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: FLOAT ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: STP-MLD ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model:FLOAT ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipmenttype and model in Section E on Pae 2). ❑ Other(specify equipment type and model in Section E on Pae 2). <br /> Dispenser ID: 1_2 Dispenser ID: 7;8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> Z Dispenser Containment Float(s)and Chains . Z Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3_4 Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). ❑Shear Valve(s). <br /> Z Dispenser Containment Floats and Chain(s). ❑Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 55-66 Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s), Model: <br /> Z Shear Valve(s). ❑Shear Valve(s), <br /> Z Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include i iformation for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/service.{ in ccordance with the manufacturers' <br /> guidelines. Attached to the Certification is information(e.g. manufacturers' checklists) necessary to ierify that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the <br /> report; (check all that apply): ❑ System set-up ❑ Alarm history report <br /> —7Technician Name(print): ROBERT NEIMEYER Signature: = - <br /> Certification No: 06043717 License: 803705 <br /> Testing Company Name: TANK-TEK .NVIRONMENTAL CORPORATION Phone No: (707)446-6151 <br /> Address: 607 ELMIRA RD, PMB 336, VACAVILLE, CA 95687 Date of Testing/Servicing: JUNE 21, 2007 <br /> Page 1 of 3 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.