COMPLIANCE INFO_1999-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_1999-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 2:19:55 PM
Creation date
6/23/2020 6:54:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2007
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_1999-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br />the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br />within 30 days of test date. <br />A. General Information <br />Signature:�� <br />Facility Name: VALLEY PACIFIC CARDLOCK #152 <br />Bldg. No.: <br />Site Address: 930 E. VICTOR RD <br />City: LODI Zip: 95240 <br />Facility Contact Person: MIKE ELIASON <br />Contact Phone No.: (209) 948-9412 <br />Make/Model of Monitoring System: ►NOON TS2001 <br />Model: FLOAT <br />I Date of Testing/Servicing: JUNE 29, 2006 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: REGULAR <br />Signature:�� <br />Tank ID: <br />License: 803705 <br />Z In -Tank Gauging Probe. <br />Model: MAG <br />❑ In -Tank Gauging Probe. <br />Model: <br />Z Annular Space or Vault Sensor. <br />Model: FLOAT <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: FLOAT <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Z Mechanical Line Leak Detector. <br />Model: FXIV <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: FLOAT <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (speciLy a ui ment a and <br />model in Section E on Page 2). <br />❑ Other(specify equipment a and model in Section E on Page 2). <br />Tank ID: SUPER <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: MAG <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: FLOAT <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: FLOAT <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Z Mechanical Line Leak Detector. <br />Model: FXIV <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: FLOAT <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (s eci a ui ment type and model in Section E on Pae 2). <br />❑ Other (specify equipment e and model in Section E on Pae 2). <br />Dispenser ID: 11=2 <br />Dispenser ID: 7_8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />Z Shear Valve(s). <br />Z Dis enser Containment Floats and Chain(s). <br />Z Dispenser Containment Floats and Chain(s). <br />Dispenser ID: 33=4 <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Z Shear Valve(s). <br />❑ Shear Valve(s). <br />Z Dis enser Containment Floats and Chain(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />Dispenser ID: 55=6 <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Z Shear Valve(s). <br />❑ Shear Valve(s). <br />Z Dis enser Containment Floats and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to the Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a <br />Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the <br />report; (check all that apply): Z System set-up Z Alarm history report <br />Technician Name (print): ROBERT NE/MEYER <br />Signature:�� <br />Certification No: 06043717 <br />License: 803705 <br />Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATIONPhone <br />No: (707) 446-6151 <br />Address: 607 ELMIRA RD, PMB 336, VACAVILLE, CA 95687 <br />Date of Testin Servicin <br />JUNE 29, 2006 <br />Page 1 of 3 <br />Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.