Laserfiche WebLink
MONIT&WNG SYSTEM CETIFI TION <br /> For 17se By All Jurisdictions Within the State of California RECEIVED <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations AA <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be p e o jH <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to thea er/o erator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> AENTAL <br /> A. General Information HEALTH DEPARTMENT <br /> Facility Name: SOUTH BAY TIRE Bldg.No.: <br /> Site Address: 1501 W CHARTER WAY City: STOCKTON Zip: 95206 <br /> Facility Contact Person: MIKE ELIASON Contact Phone No.: (209)948-9412 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: 3/27/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check t e apero nate boxes to indicatespecific a uiment inspected/service <br /> Tank ID: 87 Tank ID: DIESEL <br /> ®In-Tank Gauging Probe. Model: MAG ®In-Tank Gauging Probe. Model: MAG <br /> ®Annular Space or Vault Sensor. Model: 420 ®Annular Space or Vault Sensor. Model: 420 <br /> ®Piping Sump/Trench Sensor(s). Model: 208 ®Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: MLD STP ®Mechanical Line Leak Detector. Model: LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: FLAPPER ®Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 7 SAT Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ❑Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ® System set-up ®Alarm history report <br /> Technician Name(print): RICHARD THOMAS Signature: — vk---5 <br /> Certification No.: B34022 License.No.: 803705 <br /> Testing Company Name: TANK TEK ENVIRONMENTAL CORPORATION Phone No.:(707)446-6151 <br /> Testing Company Address: 607 ELMIRA ROAD,PMB 336, VACAVILLE, CA 95687 Date of Testing/Servicing: 3/2712014 <br /> Page 1 of 4 <br /> UN-036— www.unidoes.org Rev.01/17/08 <br />