COMPLIANCE INFO_2008-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2008-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:46:42 AM
Creation date
6/23/2020 6:54:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2016
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205 q)-71 g �O DSSmi'7 <br /> -6232 �;-• <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/eh ; <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION RET "` L" <br /> Facility Facility Inspection <br /> Name: Valley Pacific Charter Cardlock Address: 1501 W. Charter Way, Stockton Date: Mar 27, 2014 <br /> Facility Title: <br /> Phone: <br /> Contact: Mike Eliason Cardlock Manager (209) 993-8793 <br /> InsType: <br /> X Routine X Monitoring System Certification Installation Complaint-ID#: Other: <br /> (Authority HSC 25289) <br /> Consentfor. {Inspection --Sampling XPhotos Granted by:James Abbott Title: Cardlock Technician <br /> Monitoring LPipingOverfill <br /> Panel: Veeder-Root TLS-350ste : XPressudzed --Suction Gravity prevention: XMechanical Audible/visual <br /> UST 45 <br /> Product <br /> ------------------ <br /> -- ---------------------------------------------------DSL ----- -------------- - ----- - - - - -- - - - - - - - -- - <br /> Designated ICC Exp.4/1/15 <br /> Violations: XM1-Release Detection M2-Release Prevention M3-Both <br /> Operator: Mike Eliason Date: <br /> On Site Service Richard ThOtTtaS ICC Exp• 12/27/14 Manufacturer's <br /> Technician: Date: Training: VR x. 12/9/14 VMI X. 12/17/14 <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> � yy yyC1=Class 1 violation C2=Class 2 violation M Minor violation <br /> _00111 <br /> SIS I It1___ �+�� Its' ak' f 4I.. I, "." JI <br /> vS` Y zk��l f� �,r +;I,._., 1 .:� I,, -x., �, •„ :_~` .�i,.'. f�u� :t l ;..,•:; -,i'I 1, <br /> .o. ,tet. a»r �s ....,.«rS1' ,,. 't,,. ."- 18b �°.. , '�}tlri rofIPE f �Yi �i i t F i <br /> �'_,.. �t�'�3, <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> re lacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (Mt) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not re aired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily'close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan, response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> rodud was not re orted to the EHD within 24 hours <br /> Inspector: Received By: Title: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.