My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2008-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:46:42 AM
Creation date
6/23/2020 6:54:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2016
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone. (209) 468-3420 Fax: (209) 468-3433 Web: www.sjaov.org/ehdtunitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Fatality Valle Pacific Petroleum Svcs. Fddrey 1501 W. Charter Way, Stockton Inspection Mar 20, 2012 <br />Name: y Address: y Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION & MONITORING SYSTEM CERTIFICATION <br />Class 11 violations: (305) <br />305. The Bravo float and chain in the satellite UDC sump and the dispenser 3/4 UDC sump failed to stop <br />the flow of product at the dispenser when tested. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />The service technician adjusted the chain in the dispenser 3/4 UDC and verified functionality. Correct <br />the satellite UDC sump immediately by having a properly licensed, trained, and certified contractor <br />replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain a <br />permit within one business day from the EHD. If the failed component can't be replaced immediately, <br />there is a possibility that the diesel UST system may be red tagged to prevent fuel inputs. <br />REPEAT VIOLATION <br />305. The north piping transition sump sensor failed to activate an audible and visual alarm when tested <br />to ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />The float in the sensor was replaced and the sensor was retested during the inspection. <br />Complete and submit a copy of the Return to Compliance Certification to the EHD by April 20, 2012 <br />along with a statement documenting the corrective actions that have been or will be taken for each <br />violation and any supporting paperwork. <br />Provided: Return to Compliance Certification form, Schedule of FREE classes <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.