My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2008-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 8:46:42 AM
Creation date
6/23/2020 6:54:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2016
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231989_1501 W CHARTER_2008-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary Containment Testing Report Form - Page 2 of 5 <br />D. Testing of Tank Annular SpacesNaults <br />n <br />® N/A (No tanks have secondary containment) <br />Test Method Developed By: ❑ Tank Manufacturer; ® Industry Standard; ❑ PE; ❑ Other (Spec): <br />Test Method Used: ❑ Pressure; ® Vacuum; ❑ Hydrostatic; ❑ Other (Specify): <br />Test Equipment Used: gauge <br />Equipment Resolution: 0.5" HG <br />Tank #: <br />Tank #: <br />Tank #: <br />Tank #: <br />Is Tank Exempt From Testing? <br />❑ Yes; ❑ No <br />❑ Yes; ❑ No <br />❑ Yes; ❑ No <br />❑ Yes; ❑ No <br />Tank Capacity (gallons): <br />Pipe/Trench Model: <br />Dualloy <br />Product/Grade Stored in Tank: <br />Product/Grade in Line: <br />Diesel <br />Tank Manufacturer: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test (minutes): <br />30 Min. <br />Tank Model: <br />Test Start Date/Time: <br />3:00 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test (minutes): <br />Initial Reading (Rt): <br />5.2 PSI <br />Test Start Time: <br />Test End Date/Time: <br />4:00 <br />Initial Reading (RI): <br />Final Reading (RF): <br />5.2 PSI <br />Test End Time: <br />Change in Reading (RF — RI): <br />0.0 PSI <br />Final Reading (RF): <br />Pass/Fail Threshold or Criteria: <br />0.0 PSI <br />Change in Reading (RF— Rj): <br />Test Result: <br />® Pass; ❑ Fail <br />Pass/Fail Threshold or Criteria: <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />Test Result: <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />Was leak detection sensor <br />properly replaced and verified <br />as functional after testing? <br />F-1 Yes; [—]No; <br />F-1N/A (Not Removed) <br />El Yes; F] No; <br />❑ N/A (Not Removed) <br />F-1 Yes; El No; <br />❑ N/A (Not Removed) <br />❑Yes; ❑ No; <br />E]N/A (Not Removed) <br />E. Testing of Secondary Piping or Containment Trenches ❑ N/A (No piping 2° containment) <br />Test Method Developed By: ❑ Pipe/Trench Manufacturer; ® Industry Standard; ❑ PE; ❑ Other (Specie): <br />Test Method Used: ® Pressure; ❑ Vacuum; ❑ Hydrostatic; ❑ Other (Specify): <br />Test Equipment Used: gauge <br />Equipment Resolution: 0.2 PSI <br />Pipe Run #: <br />Pipe Run #: 6 SAT <br />Pipe Run #: 7 SAT <br />Pipe Run #: <br />Pipe/Trench Manufacturer: <br />Ameron <br />Ameron <br />Pipe/Trench Model: <br />Dualloy <br />Dualloy <br />Product/Grade in Line: <br />Diesel <br />Diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test (minutes): <br />30 Min. <br />30 Min. <br />Test Start Date/Time: <br />3:00 <br />3:00 <br />Initial Reading (Rt): <br />5.2 PSI <br />5.2 PSI <br />Test End Date/Time: <br />4:00 <br />4:00 <br />Final Reading (RF): <br />5.2 PSI <br />5.2 PSI <br />Change in Reading (RF — RI): <br />0.0 PSI <br />0.0 PSI <br />Pass/Fail Threshold or Criteria: <br />0.0 PSI <br />0.0 PSI <br />Test Result: <br />® Pass; ❑ Fail <br />® Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />❑ Pass; ❑ Fail <br />IIN-054 - 2/5 www.unidoes.org 02/26/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.